Repair of Tendon Disruption Using a Novel Synthetic Fiber Implant in Dogs and Cats: The Surgical Procedure and Three Case Reports

Author:

Buttin Philippe1,Goin Bastien23,Cachon Thibaut2,Viguier Eric2ORCID

Affiliation:

1. Itinerant Surgeon, 471 Chemin de Ronzier, Villaz 74370, France

2. Université de Lyon, VetAgro Sup, ICE, Marcy l’Etoile 69280, France

3. Novetech Surgery 98000, Monaco

Abstract

Surgical management of tendon rupture is challenging. One concern is to provide adequate tensile strength to prevent distraction during weight-bearing and gap formation following repair, associated with an increased risk of repair failure. Additional challenges may arise from the nature or the chronicity of the lesion. In the event of avulsion, when the tendon is torn off at the bone insertion, its reinsertion on the bone is generally difficult and may even be impossible in the presence of an avulsion fracture, especially when the bone fragment is too small or fragmented. Repair management is also complicated in chronic cases, as degeneration of the tendon may lead to excessive scar tissue formation, tendon retraction, and muscle atrophy, resulting in a large gap and inadequate tissue for reconstruction. The authors describe the surgical procedure for implanting a novel implant, illustrated by three characteristic clinical cases: (1) an acute Achilles tendon avulsion; (2) a chronic patellar tendon rupture; and (3) a chronic avulsion fracture of the triceps tendon. In these three cases, complete recovery of the function was observed at the last clinical evaluation (6 or 8 months), and no complication was noted. A splinted dressing (6 to 8 weeks) was used successfully in two cases. A resin cast (8 weeks) was preferred in case 1, a very active dog. In conclusion, this novel implant represents a simple procedure for the effective repair of chronic tendon rupture, as well as an effective tendon reinsertion on the bone and adequate support for bone tendon healing in the treatment of tendon avulsion, even in cases of fragmented bone fracture. The thinness of the implant facilitates its insertion into the native tendon, while the bone-screw-implant interface provides immediate and lasting mechanical support. This may facilitate the healing process and potentially shorten the period of immobilization.

Publisher

Hindawi Limited

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3