Treatment with Aortic Stent Graft Placement for Stanford B-Type Aortic Dissection in a Patient with an Aberrant Right Subclavian Artery

Author:

Kawatani Yohei1,Hayashi Yujiro1,Ito Yujiro1,Kurobe Hirotsugu1,Nakamura Yoshitsugu1,Suda Yuji1,Hori Takaki1

Affiliation:

1. Department of Cardiovascular Surgery, Chiba-Nishi General Hospital, 107-1 Kanegasaku, Matsudo-Shi, Chiba-ken 2702251, Japan

Abstract

A 71-year-old man visited our hospital with the chief complaint of back pain and was diagnosed with acute aortic dissection (Debakey type III, Stanford type B). He was found to have a variant branching pattern in which the right subclavian artery was the fourth branch of the aorta. We performed conservative management for uncomplicated Stanford type B aortic dissection, and the patient was discharged. An ulcer-like projection (ULP) was discovered during outpatient follow-up. Complicated type B aortic dissection was suspected, and we performed thoracic endovascular aortic repair (TEVAR). The aim of operative treatment was ULP closure; thus we placed two stent grafts in the descending aorta from the distal portion of the right subclavian artery. The patient was released without complications on postoperative day 5. Deliberate sizing and examination of placement location were necessary when placing the stent graft, but operative techniques allowed the procedure to be safely completed.

Publisher

Hindawi Limited

Subject

Aerospace Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3