The Efficacy of Clinical Tests to Diagnose Evaporative Dry Eye Disease Related to Meibomian Gland Dysfunction

Author:

Paugh Jerry R.1ORCID,Nguyen Tiffany1,Sasai Alan1ORCID,Chen Elaine1ORCID,De Jesus Melinda Thomas1ORCID,Kwan Justin1,Nguyen Andrew Loc2,Farid Marjan3ORCID,Garg Sumit3ORCID,Jester James V.34

Affiliation:

1. Southern California College of Optometry, Marshall B. Ketchum University, Fullerton, CA, USA

2. Department of Mathematics, California State University, Fullerton, CA, USA

3. Gavin Herbert Eye Institute, University of California, Irvine, CA, USA

4. Biomedical Engineering, University of California, Irvine, CA, USA

Abstract

Objectives. To determine the efficacy of widely available subtype clinical tests to characterize evaporative dry eye disease (EDED) related to meibomian gland dysfunction (MGD) compared to normal and to validate those clinical cut points in an independent sample. Methods. A diagnostic accuracy study (52 subjects), an investigator-masked study, was followed by a larger independent sample (364 subjects) analysis to confirm efficacy in normal and EDED subjects. All subjects were 18 years of age and older and were classified using a battery of clinical tests for dry eye that included symptoms, tear meniscus height, tear stability, ocular staining, evaporative-specific tests, and the Schirmer I test. Results. Normal (nondry eye; n = 26) and EDED (n = 26) subjects completed the efficacy study. The global tests of tear breakup time, staining, and symptoms all produced AUCs ≥ 0.70, representing acceptable discrimination. EDED-specific tests of eyelid marginal signs, gland secretion quality, and gland loss did not demonstrate acceptable test efficacy or differences between normal and EDED subjects. In a larger, independent sample of normal and EDED subjects, gland secretion quality and eyelid marginal score achieved acceptable diagnostic levels: AUCs of 0.789 (CI: 0.734–0.844) and 0.729 (CI: 0.648–0.810), respectively, but not lipid interferometry grade or lower eyelid gland dropout estimated using meiboscopy. Conclusions. Meibomian gland secretion quality is an efficient and useful functional indicator in EDED and should be incorporated into core outcome sets for this dry eye subtype.

Funder

Alcon

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3