Numerical Simulation of Thrombolysis in Robot-Assisted Retinal Vein Cannulation

Author:

Li Shunlei1,Pan Jiawen23,Ji Juan4ORCID,Wang Guanghang3,Qi Baobao1

Affiliation:

1. Beijing Key Laboratory of Advanced Manufacturing Technology, Beijing University of Technology, Beijing 100124, China

2. Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650031, China

3. College of Future Technology, University of Chinese Academy of Sciences, Beijing 100049, China

4. Department of Pathology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu 610041, China

Abstract

Robot-assisted retinal cannulation is an eye surgical procedure which can dissolve the obstruction by using robot to inject anticoagulant into occluded vessel. The current research on the critical parameters of cannulation for human is scarce because of the immature technology. Considering the influence of microneedle, this work investigated the effects of drug concentration, injection velocity, injection position, and size of clot on cannulation by theoretical analysis and finite element analysis. For finite element analysis, the multiphysics continuum model was established to demonstrate species transport and reaction which simulates the entire lytic process of the occlusive clot, and four cell zones were established to describe the generation of plasmin (PLS) with the addition of tissue-type plasminogen activator (tPA) and fibrinolysis of clot by importing subroutines into each cell zone under the conditions of constant clot size and variable size, respectively. The results imply that the most efficient value of tPA concentration is 50 nM, injection velocity is 60 mm/s for clot length of 0.1 mm, and the best position to insert the cannula is 0.5 mm in front of the thrombus. For different clot lengths of 0.1 mm to 0.6 mm, the optimal range of tPA concentration and injection velocity is from 20 nM to 70 nM and from 40 mm/s to 60 mm/s, respectively, and explores the reasonable injection position of 0.3 mm to 0.5 mm in front of clot in a vein of 100 μm. This conclusion can be used to perform robot-assisted cannulation surgery to improve fibrinolytic efficiency.

Publisher

Hindawi Limited

Subject

Multidisciplinary,General Computer Science

Reference34 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3