The Effect Analysis of Carrier Gas Flow Rate on the Rapid Gas Chromatographic Separation System

Author:

Zhang Xu1ORCID,Zhang Sixiang2,Zhou Wei2,Qi Yang1

Affiliation:

1. Tianjin Key Laboratory of High Speed Cutting and Precision Machining, School of Mechanical Engineering, Tianjin University of Technology and Education, Tianjin, 300222, China

2. School of Mechanical Engineering, Hebei University of Technology, Tianjin, 300100, China

Abstract

Odor pollution did not only disturb the human normal life but also aroused the attention of environmental researchers and environmental protection departments. Therefore, the research on odor detecting method and instrument is important to theory and application. On this basis, the self-developed microfluidic chip capillary column is used in our odor detecting system. In this paper, lead the chip column into the chromatography separation system, with its small size, high efficiency, easy integration, and other characteristics to replace the original traditional column. The chip column was used in many gas experiments for several typical VOCs. At different carrier gas flow rates, the baseline value, toluene response, and toluene and methyl sulfide mixed gas separation were compared to verify the experiment to determine the optimal carrier gas flow rate in accordance with its response and separation degree. Under the premise of ensuring column efficiency as high as possible, it is determined that the optimal carrier gas flow rate is 6 ml/min. This paper shows the most proper carrier gas flow rate of our odor detecting system with the self-developed microfluidic chip capillary column.

Funder

Tianjin University of Science and Technology

Publisher

Hindawi Limited

Subject

Biomedical Engineering,Bioengineering,Medicine (miscellaneous),Biotechnology

Reference14 articles.

1. Liquid transport in micro and submicron channels;J. Pfahler;Proceedings of SPIE,1992

2. Research progress and application of microfluidic chip technology;M. Yu;Plant Protection,2014

3. Development of the micro gas chromatography columns for malodorous gas detection;L. Yang;Micronanoelectronic Technology,2014

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献