Diagnostic Significance of 3D Automated Breast Volume Scanner in a Combination with Contrast-Enhanced Ultrasound for Breast Cancer

Author:

Yuan Quan1ORCID,Song Canxu1ORCID,Tian Yan1ORCID,Chen Nan2ORCID,He Xing1ORCID,Wang Ying1ORCID,Han Pihua2ORCID

Affiliation:

1. Department of Ultrasound, Shaanxi Provincial Cancer Hospital, Xi’an 710061, China

2. Department of Breast Surgery, Shaanxi Provincial Cancer Hospital, Xi’an 710061, China

Abstract

The incidence of cancer is increasing today, particularly lung and chest cancer. Employing novel methods to detect cancer in its earliest stages and discover painless, noninvasive treatments are urgently needed. The goal of the proposed study is to investigate the value of automated breast volume scanning (ABUS) in conjunction with contrast-enhanced ultrasonography (CEUS) in properly diagnosing breast cancer in its early stages and the effectiveness of neoadjuvant chemotherapy (NAC) in treating the disease. For the research study, information on 98 patients who had NAC and surgery in the breast surgery department of the Shaanxi Provincial Cancer Hospital has been gathered. All patients have received four cycles of NAC and underwent conventional ultrasound (HUSS), CEUS, ABUS, and pathological examination. At the same time, receiver operating characteristic (ROC) curve analysis, single factor, multiple linear regression, and other methods have also been used to analyze the diagnostic efficacy of breast cancer and NAC efficacy evaluation results. The study of this paper is totally based on the data collected from Shaanxi Provincial Cancer Hospital. The statistical and computational analyses are performed on the data collected for drawing inferences. When the findings are compared to the results of the pathological examination, HUSS has demonstrated a significant distinction between benign and malignant diagnoses with a statistical value of P < 0.05 .ABUS combined with CEUS has shown no considerable differences in correlation study. Except for negative likelihood ratio, the diagnostic performance indexes of CEUS+ ABUS are substantially higher than HHUS with P < 0.05 . ROC curve analysis is also performed which shows that CEUS and ABUS combination has higher precision in the analysis of breast cancer. ABUS pooled with CEUS shows great application value in the judgment of breast cancer as per the results obtained from the statistical analysis on data of 98 patients.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3