Does Electrode Sensor Positioning over Motor Points Affect Different Portions of Quadriceps Muscle Architecture during Submaximal Evoked Torque?

Author:

Ventura Álvaro1ORCID,Gomes Leandro1,Cavalcante Jonathan2,Vieira Denis3,Sousa Caio Victor4,Marqueti Rita de Cassia5ORCID,Babault Nicolas6ORCID,Durigan João Luiz7ORCID

Affiliation:

1. Physical Therapist from University of Brasília, Distrito Federal, Brazil

2. Graduate Program of Rehabilitation Sciences, University of Brasília, Distrito Federal, Brazil

3. Federal Institute of Brasília, Distrito Federal, Brazil

4. Loyola Marymount University, Los Angeles, California, USA

5. Laboratory of Molecular Analysis, Graduate Program of Rehabilitation Sciences, University of Brasília, Distrito Federal, Brazil

6. Centre d’Expertise de la Performance, INSERM UMR1093-CAPS, University of Burgundy Franche-Comté, UFR des Sciences du Sport, F-21000 Dijon, France

7. Laboratory of Muscle and Tendon Plasticity, Graduate Program of Rehabilitation Sciences, University of Brasília, Distrito Federal, Brazil

Abstract

Background and Objectives. Few studies have evaluated differences in muscle architecture in quadriceps femoris constituents with sensor electrodes positioned over vastus lateralis (VL) and vastus medialis (VM) motor points during a neuromuscular electrical stimulation (NMES) session. We aimed to investigate the changes in muscle architecture of the rectus femoris (RF), VL, VM, and vastus intermedius (VI) portions during evoked contractions with sensor electrodes placed over VL and VM motor points. Materials and Methods. The study is a crossover, repeated-measure design, conducted with healthy males aged 24.0 ± 4.6 years. Ultrasonography at rest and evoked contraction at 40% of maximum voluntary contraction (MVC) were used to assess the pennation angle ( θ p ) and fascicle length (Lf) of RF, VL, VM, and VI portions. Results. The mean torque observed was 201.14 ± 50.22  N.m during MVC and at 40% of MVC was 80.45 ± 20.08  N.m. There was no difference for θ p comparing four components of the quadriceps femoris ( p = 0.27 ). There was a significant ( p < 0.05 ) muscle evoked contraction interaction for Lf without relevant clinical importance to the study. Conclusions. There is no difference in the changes in the muscle architecture of quadriceps femoris constituents during stimulation with the electrodes placed on the VL and VM motor points. Therefore, clinicians can choose either VL or VM motor points for sensor electrode positioning and expect similar muscle architecture adaptation for a given evoked torque. Future clinical studies should be conducted to establish the optimal electrode positioning over different portions of the quadriceps muscle to optimize more rational NMES clinical settings.

Funder

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Publisher

Hindawi Limited

Subject

Electrical and Electronic Engineering,Instrumentation,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3