Successive Approximation Register Analog-to-Digital Converter (SAR ADC) for Biomedical Applications

Author:

Arafa Kawther I.12ORCID,Ellaithy Dina M.2ORCID,Zekry Abdelhalim1ORCID,Abouelatta Mohamed1ORCID,Shawkey Heba2ORCID

Affiliation:

1. Electronics and Communications Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt

2. Microelectronics Department, Electronics Research Institute (ERI), Cairo 11843, Egypt

Abstract

This study presents a survey of the most promising reported SAR ADC designs for biomedical applications, stressing advantages, disadvantages, and limitations, and concludes with a quantitative comparison. Recent progress in the development of a single SAR ADC architecture is reviewed. In wearable and biosensor systems, a very small amount of total power must be devoured by portable batteries or energy-harvesting circuits in order to function correctly. During the past decade, implementation of the high energy efficiency of SAR ADC has become the most necessary. So, several different implementation schemes for the main components of the SAR ADC have been proposed. In this review study, the various circuit architectures have been explained, beginning with the sample and hold (S/H) switching circuits, the dynamic comparator, the internal digital-to-analog converter (DAC), and the SAR control logic. In order to achieve low power consumption, numerous different configurations of dynamic comparator circuits are revealed. At the end of this overview, the evolutions of DAC architecture in distinct biomedical applications today can make a tradeoff between resolution, speed, and linearity, which represent the challenges of a single SAR ADC. For high resolution, the dual split capacitive DAC (CDAC) array technique and hybrid capacitor technique can be used. Also, for ultralow power consumption, various voltage switching schemes are achieved to reduce the number of switches. These schemes can save switching energy and reduce capacitor array area with high linearity. Additionally, to increase the speed of the conversion process, a prediction-based ADC design is employed. Therefore, SAR ADC is considered the ideal solution for biomedical applications.

Publisher

Hindawi Limited

Subject

Electrical and Electronic Engineering,Electronic, Optical and Magnetic Materials

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Analysis and Design of High-Energy-Efficiency Amplifiers for Delta-Sigma Modulators;Active and Passive Electronic Components;2023-11-23

2. An overview of principles and types of ADC and DAC;Journal of Physics: Conference Series;2023-11-01

3. Voltage-controlled oscillator based analog-to-digital converter in 130-nm CMOS for biomedical applications;Journal of Electrical Systems and Information Technology;2023-08-21

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3