Development of UV Spectrophotometric Procedures for Determination of Amlodipine and Celecoxib in Formulation: Use of Scaling Factor to Improve the Sensitivity

Author:

Attimarad Mahesh1ORCID,Venugopala Katharigatta Narayanaswamy12ORCID,Aldhubiab Bandar E.1ORCID,Nair Anroop Balachandran1,SreeHarsha Nagaraja1ORCID,Pottathil Shinu3,Akrawi Sabah H.1ORCID

Affiliation:

1. Department of Pharmaceutical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf, Al-Ahsa 31982, Saudi Arabia

2. Department of Biotechnology and Food Technology, Durban University of Technology, Durban 4001, South Africa

3. Department of Biomedical Sciences, College of Clinical Pharmacy, King Faisal University, Al-Hofuf, Al-Ahsa 31982, Saudi Arabia

Abstract

FDA has recently approved a new fixed-dose combination of amlodipine besylate (AMD) and celecoxib (COX) for the treatment of hypertension and osteoarthritis. No analytical method has been reported for analysis of these two analytes so far. Hence, to monitor the quality and quantity in the formulation of AMD and COX a simple, accurate, precise, economical, and eco-friendly spectroscopic analytical method has been established. The first method involves the determination of AMD and COX by the first derivative UV spectroscopic method with scaling factor 10. However, the second method was based on the direct measurement of UV absorbance of AMD at 364.3 nm and ratio first derivative UV spectroscopic method for COX. Both methods showed good linearity in the range of 5 to 40 μg/ml for COX, whereas AMD showed linearity in the range of 0.5 to 10 μg/ml in first derivative method with scaling factor 10 and 1 to 10 μg/ml in the second method with good correlation coefficient (R2 > 0.998). Both the methods were validated for LOD, LOQ, accuracy, precision, recovery studies, and stability as per the ICH guidelines, and the validated results were well within the acceptable range. Both the methods were successfully utilized for the determination of AMD and COX in the presence of each other in the formulation, and statistically compared between the proposed methods. Therefore, the proposed procedures can be utilized for regular quality control studies.

Funder

Deanship of Scientific Research, King Faisal University

Publisher

Hindawi Limited

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3