Purpose. Diagnose keratoconus by establishing an effective logistic regression model from the data obtained with a Scheimpflug-Placido cornea topographer. Methods. Topographical parameters of 125 eyes of 70 patients diagnosed with keratoconus by clinical or topographical findings were compared with 120 eyes of 63 patients who were defined as keratorefractive surgery candidates. The receiver operating character (ROC) curve analysis was performed to determine the diagnostic ability of the topographic parameters. The data set of parameters with an AUROC (area under the ROC curve) value greater than 0.9 was analyzed with logistic regression analysis (LRA) to determine the most predictive model that could diagnose keratoconus. A logit formula of the model was built, and the logit values of every eye in the study were calculated according to this formula. Then, an ROC analysis of the logit values was done. Results. Baiocchi Calossi Versaci front index (BCVf) had the highest AUROC value (0.976) in the study. The LRA model, which had the highest prediction ability, had 97.5% accuracy, 96.8% sensitivity, and 99.2% specificity. The most significant parameters were found to be BCVf ( p = 0.001 ), BCVb (Baiocchi Calossi Versaci back) ( p = 0.002 ), posterior rf (apical radius of the flattest meridian of the aspherotoric surface in 4.5 mm diameter of the cornea) ( p = 0.005 ), central corneal thickness ( p = 0.072 ), and minimum corneal thickness ( p = 0.494 ). Conclusions. The LRA model can distinguish keratoconus corneas from normal ones with high accuracy without the need for complex computer algorithms.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3