Effects of Er, Cr: YSGG Laser on Shear Bond Strength of the Orthodontic Brackets for 5 and 10 Seconds: An In Vitro Study

Author:

Bagwan Ahmed A.1ORCID,Abuaffan Amal H.2ORCID,Alrahlah Ali3ORCID,Hassan AL-Gunaid Talat4ORCID

Affiliation:

1. Department of Orthodontics, School of Dentistry, University of Khartoum, Khartoum, Sudan

2. Department of Orthodontics, Pedodontics and Preventive Dentistry, University of Khartoum, Khartoum, Sudan

3. Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Engr. Abdullah Bugshan Research Chair for Dental and Oral Rehabilitation, Riyadh 11545, Saudi Arabia

4. Department of Pediatric Dentistry and Orthodontics, College of Dentistry, Taibah University, Madinah, Saudi Arabia

Abstract

Objectives. The study designed to compare the effect of erbium, chromium: yttrium-scandium-gallium-garnet (Er, Cr: YSGG) laser at different power outputs and short periods of time (5 and 10 s) and acid etching on the shear bond strength (SBS) and failure mode of metallic orthodontic brackets. Material and methods. A total of sixty-nine human premolars extracted for orthodontic purposes were used. 60 teeth were randomly assigned to one of the five treatment groups. (n = 12): group 1: 37% phosphoric acid etching and groups 2–5: the enamel surface irradiated by the Er, Cr: YSGG laser operated at different power outputs (1 W, 1.5 W, 2 W, and 2.5 W), each laser group was divided into two subgroups (n = 6) according to exposure time (5 s and 10 s). Nine teeth were not subjected to SBS testing but were prepared for scanning electron microscopy (SEM). The nonparametric Kruskal–Wallis test was used to evaluate the data; the SBS and adhesive remanent index (ADI) were evaluated. Results. The mean SBS for all laser groups and the acid-etched group were comparable, with no significant differences except for the 1 W group for 5 and 10 s and the 1.5 W group for 5 s. For the ARI scores, no statistically significant difference was found among the groups ( P = 0.059 ), and the majority of the samples had ARI type 2 or 3. Conclusion. The laser irradiation at 2 and 2.5 W for 5 s was similar to that produced by acid etching, whereas the laser irradiation at 2 and 2.5 W at 10 s was higher compared with that obtained with acid etching and adequate to etch the enamel.

Funder

King Saud University

Publisher

Hindawi Limited

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3