Reconstruction Algorithm-Based CT Imaging for the Diagnosis of Hepatic Ascites

Author:

Zhang Huitao1ORCID,Lv Wenhao1ORCID,Diao Haofeng2ORCID,Shang Li1ORCID

Affiliation:

1. Department of Gastroenterology, The No.4 People’s Hospital of Hengshui City, Hengshui 053000, China

2. Department of Spine Surgery, The No.4 People’s Hospital of Hengshui City, Hengshui 053000, China

Abstract

The study was aimed at exploring the diagnostic value of artificial intelligence reconstruction algorithm combined with CT image parameters on hepatic ascites, expected to provide a reference for the etiological evaluation of clinical abdominal effusion. Specifically, the adaptive iterative hard threshold (AIHT) algorithm for CT image reconstruction was proposed. Then, 100 patients with peritoneal effusion were selected as the research subjects. After 8 cases were excluded, the remaining was divided into 50 cases of the S1 group (hepatic ascites) and 42 cases of the D0 group (cancerous peritoneal effusion). Gemstone energy spectrum CT scanning was performed on all patients, and CT image parameters of the two groups were compared. It was found that CT value of mixed energy, CT value of 60-100 KeV single energy, concentration value of water (calcium), concentration value of water (iodine), and slope of energy spectrum curve in the S1 group were significantly lower than those in the D0 group ( P < 0.05 ). The effective atomic number in the S1 group was significantly higher than that in the D0 group ( P < 0.05 ). Of the 50 patients in the S1 group, 3 (6%) had an ascending and 47 (94%) had a descending spectral curve. Of the 42 patients in the D0 group, 37 (88.1%) had an ascending and 5 (11.9%) had a descending spectral curve. The sensitivity and specificity of water (iodine) were 0.927 and 0.836, respectively. The sensitivity and specificity of water (calcium) were 0.863 and 0.887, respectively. For different scan ranges ([0,90]; [0,120]), root mean square error (RMSE) of AIHT reconstructed image was significantly smaller than that of traditional algorithm, while peak signal-to-noise ratio (PSNR) was opposite. The differences were statistically significant ( P < 0.05 ). In conclusion, AIHT-based CT images can better display the distribution of hepatic ascites, and the parameters of CT value, effective atomic number, water (iodine), water (calcium), and spectral curve can all provide help for the identification of hepatic ascites. Especially, water (iodine) and water (calcium) demonstrated high diagnostic performance of hepatic ascites.

Publisher

Hindawi Limited

Subject

Applied Mathematics,General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,Modeling and Simulation,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3