Biomechanics of Central Incisor Endocrowns with Different Lengths and Milled Materials after Static and Vertical Loading: A Finite Element Study

Author:

M. S. Alqahtani Waleed1,A. Yousief Salah23ORCID,Tammam Raafat4ORCID,M. Galal Rami5ORCID,Brakat Ali2ORCID,Mohamed El Sayed Hend6,Kamal Ala’a2,Noushad Mohammed2,Nassani Mohammad Zakaria2ORCID

Affiliation:

1. Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia

2. Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh 13313, Saudi Arabia

3. Department of Crown and Bridge, Faculty of Oral and Dental Medicine, Al Azhar University, Assuit Branch, Cairo 71524, Egypt

4. Department of Prosthodontics, Faculty of Dentistry, Assiut University, Assiut 71515, Egypt

5. Department of Fixed and Removable Prosthodontics, National Research Centre, Cairo, Egypt

6. Restorative Dentistry Conservative Dentistry Department, Faculty of Dentistry, Cairo University, 11 EL-Saraya Street Manial, Cairo 11553, Egypt

Abstract

Statement of Problem. The performance of central incisor endocrowns with varying crown heights and different computer-aided designs and computer-aided manufacturing materials is not clear. Purpose. The aim of this study was to compare and assess the stress distribution and failure possibility of endodontically treated central incisor protected with endocrowns with different heights, with various CAD–CAM blocks such as IPS e.max CAD, Katana Zirconia, and Zolid Fx Zirconia. Materials and Methods. A root canal-treated central incisor (plastic model) restored with an endocrown was scanned with a laser scanner to prepare a control model with a CAD software and then transferred to an FEA software. Proposed crown heights were 2, 4, and 6 mm. The model that was duplicated and restored with CAD–CAM blocks, IPS e.max CAD, Katana Zirconia, and Zolid Fx Zirconia were tested as endocrown materials. Bone geometry was simplified to be two coaxial cylinders in all models. Stress distributions under 50 N axial and oblique (with 135° angle from the vertical plane) loading were analyzed. Each model was then subjected to two occlusal loading conditions—the lingual slope of the incisal edge and the junction between incisal and middle thirds. Eighteen runs and calculations were performed to determine the endocrown height and material effect. Results. The results showed a minor or negligible effect of changing the endocrown material. Increasing endocrown height was shown to reduce stresses and deformations on most of the model components (bone, gutta-percha, periodontal ligament, and endocrown), except root and cement. Differences in deformations and stresses between the two models of 4 and 6 mm were relatively smaller (ranged between 1% and 30%) compared to those between the 2 and 4 mm models (ranged between 10% and 400%). Conclusions. The material used to fabricate endocrowns did not show considerable effect on the underlying structures. However, the endocrown design (2, 4, and 6 mm height) was shown to affect all components of the studied systems. Increasing endocrown height is recommended for bone, periodontal ligaments, and endocrown body, as it reduces stresses and deformations. On the other hand, it dramatically increases stresses on the root and cement layer. Smaller endocrown sizes represent an acceptable treatment option when there is a healthy periodontal state, while using larger sizes will be more suitable when there is a periodontal compromise with bone loss.

Funder

Dar Al Uloom University

Publisher

Hindawi Limited

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3