Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

Author:

Arriola-Villalobos Pedro12ORCID,Martinez-de-la-Casa Jose Maria23,Diaz-Valle David23,Morales-Fernandez Laura12,Fernandez-Perez Cristina4,Garcia-Feijoo Julian235

Affiliation:

1. Servicio de Oftalmología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain

2. Cooperative Research Network on Age-Related Ocular Pathology, Visual and Life Quality, Instituto de Salud Carlos III, Madrid, Spain

3. Servicio de Oftalmología, Hospital Clínico San Carlos, Departamento de Oftalmología y ORL, Facultad de Medicina, Universidad Complutense de Madrid, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain

4. Servicio de Medicina Preventiva y Salud Pública, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain

5. Instituto de Investigaciones Oftalmológicas Ramon Castroviejo, Universidad Complutense de Madrid, Madrid, Spain

Abstract

Purpose. To evaluate the long-term efficacy and safety of the iStentinjectdevice (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT).Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStentinjectdevices. Outcome measures were intraocular pressure (IOP), topical hypotensive medications required, and best-corrected visual acuity (BCVA).Results. 20 patients were enrolled. Mean follow-up was47.4±18.46months. Mean baseline IOP was19.95±3.71 mmHg with medication and26±3.11 mmHg after washout. Mean end-follow-up IOP was16.25±1.99 mmHg, representing an IOP decrease of 36.92%,9.74±3.14 mmHg (P<0.001), from baseline washout IOP. The mean number of medications was significantly reduced from1.3±0.66to0.75±0.79(P=0.017). 45% of patients were medication-free by the end of follow-up. MeanlogMARBCVA improved significantly from0.42±0.16to0.18±0.16(P<0.001). No complications of surgery were observed.Conclusion. The iStentinjectdevice combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT) and cataract.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 73 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3