1. Department of Ophthalmology, Peking University People’s Hospital, Eye Diseases and Optometry Institute, Beijing Key Laboratory of Diagnosis and Therapy of Retinal and Choroid Diseases, College of Optometry, Peking University Health Science Center, 11 Xizhimen South Street, Xicheng District, Beijing 100044, China

2. Department of Ophthalmology, Peking University International Hospital, 1 Shengmingyuan Road, Life Science Park, Changping District, Beijing 102206, China

Abstract

Purpose. To compare the total corneal astigmatism (TCA) measured by IOLMaster 700 and Pentacam and to investigate the consistency of corneal keratometry (CK) measured by IOLMaster and Pentacam. Methods. Cataract patients were retrospectively enrolled in March and April, 2021. Retrospective analysis was performed on those patients with binocular and monocular CK measured by IOLMaster and Pentacam. Results. A total of 102 patients (204 eyes) were included, 64 of whom were female (62.75%). The flat (K1) and steep (K2) CK of anterior corneal surface (ACS) and flat (TK1) and steep (TK2) of total cornea measured with IOLMaster 700 were 44.16 ± 1.60 D , 45.09 ± 1.68 D , 44.12 ± 1.62 D , and 45.14 ± 1.69 D , respectively. Those measured with Pentacam were 44.31 ± 1.57 D , 45.22 ± 1.65 D , 44.15 ± 1.67 D , and 45.19 ± 1.82 D , respectively. The astigmatism of ACS and TCA were 0.94 ± 0.63 D and 1.02 ± 0.69 D ( p < 0.01 ) in the IOLMaster group and 0.90 ± 0.59 D and 1.05 ± 0.81 D in the Pentacam group, respectively ( p < 0.01 ). TCA measurement results of IOLMaster and Pentacam were consistent ( Pearson = 0.710 , p < 0.01 ), and there was no significant difference ( p = 0.591 ). Conclusions. Total corneal astigmatism measured by IOLMaster was consistent with that measured by Pentacam. The difference between the astigmatism of anterior corneal surface and total cornea was detected in the measurement of IOLMaster and Pentacam, respectively.

Funder

National Key R&D Program of China

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3