Abstract

BACKGROUND: Liver stiffness measurement (LSM) using transient elastography (TE) is a promising tool for the noninvasive assessment of hepatic fibrosis.OBJECTIVES: To determine the feasibility and performance of TE in a North American cohort of patients with chronic liver disease.METHODS: LSMs were obtained using TE in 260 patients with chronic hepatitis B or C, or nonalcoholic fatty liver disease from four Canadian hepatology centres. The accuracy of TE compared with liver biopsy for the prediction of significant fibrosis (Metavir fibrosis score of F2 or greater), bridging fibrosis (Metavir fibrosis score of F3 or greater) and cirrhosis (Metavir fibrosis score of F4 ) was assessed using area under ROC curves (AUROCs), and compared with the aspartate aminotransferase-to-platelet ratio index. The influence of alanine aminotransferase (ALT) levels and other factors on liver stiffness was determined using linear regression analyses.RESULTS: Failure of TE occurred in 2.7% of patients, while liver biopsies were inadequate for staging in 0.8%. Among the remaining 251 patients, the AUROCs of TE for Metavir fibrosis scores of F2 and F3 or greater, and F4 were 0.74 (95% CI 0.68 to 0.80), 0.89 (95% CI 0.84 to 0.94), and 0.94 (95% CI 0.90 to 0.97), respectively. LSM was more accurate than the aminotransferase-to-platelet ratio index for bridging fibrosis (AUROC 0.78) and cirrhosis (AUROC 0.88), but not significant fibrosis (AUROC 0.76). At a cut-off of 11.1 kPa, the sensitivity, specificity, and positive and negative predictive values for cirrhosis (prevalence 11%) were 96%, 81%, 39% and 99%, respectively. For significant fibrosis (prevalence 53%), a cut-off of 7.7 kPa was 68% sensitive and 69% specific, and had a positive predictive value of 70% and a negative predictive value of 65%. Liver stiffness was independently associated with ALT, body mass index and steatosis. The optimal LSM cut-offs for cirrhosis were 11.1 kPa and 11.5 kPa in patients with ALT levels lower than 100 U/L and 100 U/L or greater, respectively. For fibrosis scores of F2 or greater, these figures were 7.0 kPa and 8.6 kPa, respectively.CONCLUSIONS: The major role of TE is the exclusion of bridging fibrosis and cirrhosis. However, TE cannot replace biopsy for the diagnosis of significant fibrosis. Because liver stiffness may be influenced by significant ALT elevation, body mass index and/or steatosis, tailored liver stiffness cut-offs may be necessary to account for these factors.

Publisher

Hindawi Limited

Subject

Gastroenterology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3