Measuring Activated Clotting Time during Cardiac Catheterization and PCI: The Effect of the Sampling Site

Author:

Heemelaar J. C1ORCID,Berkhout T.1,Heestermans A. A. C. M.1,Zant J. C.2,de Vos A. M. J.3,Verouden N. J. W.4ORCID,Dirksen M. T.1ORCID,van Ramshorst J.1ORCID

Affiliation:

1. Department of Cardiology, Northwest Clinics, Alkmaar, Netherlands

2. Department of Clinical Chemistry, Northwest Clinics, Alkmaar, Netherlands

3. Department of Cardiology, Catharina Hospital, Eindhoven, Netherlands

4. Department of Cardiology, Amsterdam University Medical Center, Amsterdam, Netherlands

Abstract

Background/Purpose. We aimed to investigate the influence of the sampling site on the variability of ACT measurement. Activated clotting time (ACT) has been used for decades in cardiac surgery and interventional cardiology to assess unfractionated heparin activity. However, standardized protocols for the use of ACT measurement in the catheterization laboratory are lacking. Methods/Materials. After elective cardiac catheterization, ACT measurements were collected in simultaneously obtained blood samples from three different sample sites: the arterial catheter, arterial sheath, and peripheral intravenous line. Measurements were performed using the i-Stat® device (Abbott, Princeton, NJ, USA). The study was conducted with approval of the local medical ethical committee. Results. In 100 patients (mean age 67.1, 65% male), no significant differences were observed in ACT values obtained from the guiding catheter and arterial sheath (mean difference (MD) −18.3 s; standard deviation (SD) 96 s; P = 0.067 ). Contrarily, ACT values obtained from the intravenous line were significantly lower as compared to values obtained from the guiding catheter (MD 25.7 s; SD 75.5; P = 0.003 ) and arterial sheath (MD 39 s; SD 102.8; P < 0.001 ). Furthermore, ACT measurements from the arterial sheath showed a statistically significant proportional bias when compared to the other sampling sites (sheath vs. catheter, r = 0.761, P = 0.001 ; sheath vs. IVL, r = 1.013, P < 0.001 ). Conclusions. The present study shows statistical significance and possibly clinically relevant variations between ACT measurements from different sample sites. Bias in ACT measurements may be minimized by using uniform protocols for ACT measurement during cardiac catheterization.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3