Changes in Renal Function in Patients with Recurrence of Atrial Arrhythmia after an Initial Catheter Ablation

Author:

Shen Youmei1ORCID,Chen Hongwu1ORCID,Yang Gang1ORCID,Ju Weizhu1ORCID,Zhang Fengxiang1ORCID,Gu Kai1ORCID,Cui Chang1ORCID,Li Mingfang1ORCID,Chen Minglong1ORCID

Affiliation:

1. Division of Cardiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China

Abstract

Background. Impaired renal function and atrial fibrillation (AF) can form a vicious cycle. Although there have been reports on improved renal function in patients who undergo successful AF ablation, renal function in patients with recurrence of AF has not been studied separately. We explored the changes in renal function in recurrent AF patients after catheter ablation with mild renal dysfunction and the influencing factors. Methods. We retrospectively recruited nonvalvular AF (NVAF) patients with mildly impaired renal function admitted for catheter ablation and readmitted due to recurrence of AF. The estimated glomerular filtration rate (eGFR) was calculated before the index procedure and during readmission. △eGFR was defined as the difference between eGFR readmission and eGFR baseline. The same calculation applied for △CHA2DS2-VASc score. The primary endpoint was improved renal function (△eGFR >0) after AF catheter ablation in patients with atrial arrhythmia recurrence. Results. A total of 132 NVAF patients were included in this study. The mean eGFR at readmission was significantly increased compared with the eGFR at baseline before the index ablation procedure (81.5 ± 1.1 vs. 78.0 ± 0.7 ml/min/1.73 m2, P < 0.001 ). The multivariable Cox regression analysis showed that a lower △CHA2DS2-VASc score (HR: 0.42, P = 0.003 ) and paroxysmal recurrent atrial arrhythmia (HR: 2.97, P = 0.001 ) were associated with better renal function. Conclusion. In NVAF patients with mildly impaired renal function, even those with recurrence after the initial catheter ablation, we observed improvements in renal function, which was associated with a lower △CHA2DS2-VASc score and paroxysmal recurrent arrhythmia.

Funder

Key Clinical Study Project of Jiangsu Province

Publisher

Hindawi Limited

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3