Efficacy of Hi-Lo Evac Endotracheal Tube in Prevention of Ventilator-Associated Pneumonia in Mechanically Ventilated Poisoned Patients

Author:

Ghoochani Khorasani Ahmad12ORCID,Shadnia Shahin1ORCID,Mashayekhian Mohammad12,Rahimi Mitra1,Aghabiklooei Abbas13

Affiliation:

1. Department of Clinical Toxicology, Loghman-Hakim Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

2. Department of Medical Sciences, Amin Police University, Tehran, Iran

3. Department of Legal Medicine, Iran University of Medical Sciences, Tehran, Iran

Abstract

Background. Ventilator-associated pneumonia (VAP) is the most common health care-associated infection. To prevent this complication, aspiration of subglottic secretions using Hi-Lo Evac endotracheal tube (Evac ETT) is a recommended intervention. However, there are some reports on Evac ETT dysfunction. We aimed to compare the incidence of VAP (per ventilated patients) in severely ill poisoned patients who were intubated using Evac ETT versus conventional endotracheal tubes (C-ETT) in our toxicology ICU.Materials and Methods. In this clinical randomized trial, 91 eligible patients with an expected duration of mechanical ventilation of more than 48 hours were recruited and randomly assigned into two groups: (1) subglottic secretion drainage (SSD) group who were intubated by Evac ETT (n=43) and (2) control group who were intubated by C-ETT (n=48).Results. Of the 91 eligible patients, 56 (61.5%) were male. VAP was detected in 24 of 43 (55.8%) patients in the case group and 23 of 48 (47.9%) patients in the control group (P=0.45). The most frequently isolated microorganisms wereS. aureus(54.10%) andAcinetobacterspp. (19.68%). The incidence of VAP and ICU length of stay were not significantly different between the two groups, but duration of intubation was statistically different and was longer in the SSD group. Mortality rate was less in SSD group but without a significant difference (P=0.68).Conclusion. The SSD procedure was performed intermittently with one-hour intervals using 10 mL syringe. Subglottic secretion drainage does not significantly reduce the incidence of VAP in patients receiving MV. This strategy appears to be ineffective in preventing VAP among ICU patients.

Publisher

Hindawi Limited

Subject

General Agricultural and Biological Sciences,General Environmental Science

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3