Affiliation:
1. Department of Ophthalmology, Miguel Servet University Hospital, Aragonés Institute of Health Sciences, University of Zaragoza, Isabel la Católica 1-3, 50009 Zaragoza, Spain
Abstract
Background. To compare the efficacy and safety of a new ocular insert versus conventional mydriasis in cataract surgery.Methods. We selected 70 patients undergoing cataract surgery. Thirty five patients (Group 1) received instillation of mydriatic drops (tropicamide 1%, phenylephrine 10%, and cyclopentolate 1%) prior to surgery, and 35 patients (Group 2) had a Mydriasert insert (Théa Pharma) (0.28 mg of tropicamide and 5.4 mg of phenylephrine hydrochloride) placed in the inferior fornix. Pupil size before and after surgery, blood pressure, and heart rate were measured.Results. Before surgery, pupil diameter was mm in Group 1 and in Group 2 (). Twenty four hours after surgery, pupil diameter was mm in Group 1 and in Group 2 (). There were no statistically significant differences in blood pressure or heart rate between groups.Conclusions. The effect of the Mydriasert insert was similar to conventional mydriatic agents. Pupil size was restored to normal faster when using the Mydriasert insert compared with conventional mydriatic agents for pupil dilation.
Subject
General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献