False Alarm Reduction in Self-Care by Personalized Automatic Detection of ECG Electrode Cable Interchanges

Author:

Fayn Jocelyne1ORCID,Rubel Paul1ORCID

Affiliation:

1. SFR Santé Lyon-Est: eTechSanté, INSERM US7, Université de Lyon, Lyon 69372, France

Abstract

Introduction. False alarm reduction is an important challenge in self-care, whereas one of the most important false alarm causes in the cardiology domain is electrodes misplacements in ECG recordings, the main investigations to perform for early and pervasive detection of cardiovascular diseases. In this context, we present and assess a new method for electrode reversals identification for Mason-Likar based 3D ECG recording systems which are especially convenient to use in self-care and allow to achieve, as previously reported, high computerized ischemia detection accuracy. Methods. We mathematically simulate the effect of the six pairwise reversals of the LA, RA, LL, and C2 electrodes on the three ECG leads I, II, and V2. Our approach then consists in performing serial comparisons of the newly recorded 3D ECG and of the six derived ECGs simulating an electrode reversal with a standard, 12-lead reference ECG by means of the CAVIAR software. We further use a scoring method to compare these analysis results and then apply a decision tree model to extract the most relevant measurements in a learning set of 121 patients recorded in ICU. Results. The comparison of the seven sets of serial analysis results from the learning set resulted in the determination of a composite criteria involving four measurements of spatial orientation changes of QRS and T and providing a reversal identification accuracy of 100%. Almost the same results, with 99.99% of sensitivity and 100% of specificity, were obtained in two test sets from 90 patients, composed of 2098 and 2036 representative ECG beats respectively recorded during PTCA balloon inflation, a procedure which mimics ischemia, and before PTCA for control. Conclusion. Personalized automatic detection of ECG electrode cable interchanges can reach almost the maximal accuracy of 100% in self-care, and can be performed in almost real time.

Publisher

Hindawi Limited

Subject

Health Information Management,Computer Networks and Communications,Health Informatics,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3