Evaluation of Bag-Valve-Mask Ventilation in Manikin Studies: What Are the Current Limitations?

Author:

Khoury A.12ORCID,Sall F. S.12ORCID,De Luca A.12ORCID,Pugin A.2,Pili-Floury S.3,Pazart L.2,Capellier G.14

Affiliation:

1. Department of Emergency Medicine & Critical Care, University of Franche-Comté, Medical Centre, 25000 Besançon, France

2. Clinical Investigation Centre, INSERM CIC-1431, University of Franche-Comté, Medical Centre, 25000 Besançon, France

3. Department of Anaesthesia and Critical Care, University of Franche-Comté, Medical Centre, 25000 Besançon, France

4. Monash University, Melbourne, VIC 3800, Australia

Abstract

Introduction.Manikin-based studies for evaluation of ventilation performance show high heterogeneity in the analysis and experimental methods used as we pointed out in previous studies. In this work, we aim to evaluate these potential limitations and propose a new analysis methodology to reliably assess ventilation performance.Methods.One hundred forty healthcare providers were selected to ventilate a manikin with two adult self-inflating bags in random order. Ventilation parameters were analysed using different published analysis methods compared to ours.Results.Using different methods impacts the evaluation of ventilation efficiency which ranges from 0% to 45.71%. Our new method proved relevant and showed that all professionals tend to cause hyperventilation and revealed a significant relationship between professional category, grip strength of the hand keeping the mask, and ventilation performance (p=0.0049andp=0.0297, resp.).Conclusion.Using adequate analysis methods is crucial to avoid many biases. Extrapolations to humans still have to be taken with caution as many factors impact the evaluation of ventilation performance. Healthcare professionals tend to cause hyperventilation with current devices. We believe this problem could be prevented by implementing monitoring tools in order to give direct feedback to healthcare professionals regarding ventilation efficiency and ventilatory parameter values.

Funder

European Commission

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3