Affiliation:
1. Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China
Abstract
A novel all-silica fiber optic Fabry-Perot (FP) pressure sensor with pressure leading-in tube based on microbubble structure is developed and experimentally demonstrated. The FP cavity is formed by fixing the end face of the single-mode fiber (SMF) parallel to the outer surface of the microbubble, in which the microbubble with a diameter of about 318 μm is constructed at the end of silica hollow tube. When external pressure is transmitted on the inner surface of the microbubble by the pressure leading-in tube, the FP cavity length changes with the diameter of microbubble. Experimental results show that such a sensor has a linear sensitivity of approximately 4.84 nm/MPa at room temperature over the pressure range of 1.1 MPa; the sensor has a very low temperature coefficient of approximately 2 pm/°C from room temperature to 600°C. The sensor has advantages of extremely low temperature coefficient, compact structure, and small size, which has potential applications for measuring pressure in high-temperature environment.
Funder
Fund for Shanxi “1331 Project” Key Subject Construction
Subject
Electrical and Electronic Engineering,Instrumentation,Control and Systems Engineering
Cited by
7 articles.