Affiliation:
1. Mental Health Research Center of RAMS, Moscow 115522, Russia
Abstract
The aim of this study was to develop and validate a high-performance liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for analysis of the amiridine in human plasma. The analyte and internal standard (IS), zolpidem, were extracted from human plasma by solid phase extraction (SPE with SOLA cartridges) and separated on a Zorbax SB-C18 column using methanol and 0.2% formic acid in water as mobile phase. Detection was performed using an electrospray ionization source and mass spectrometric positive multireaction monitoring mode (+MRM) at a voltage capillary of +2000 V. The assay was linear over the concentration range 0.5–200 ng/mL with the lowest limit of quantification (LLOQ) of 0.5 ng/mL. The method also afforded satisfactory results in terms of the sensitivity, specificity, precision (intra- and interday %), accuracy, recovery, and the stability of the analyte under various conditions. The method can be successfully applied to pharmacokinetic studies.
Subject
General Earth and Planetary Sciences,General Engineering,General Environmental Science
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献