A Comparison of Performance of Endotracheal Intubation Using the Levitan FPS Optical Stylet or Lary-Flex Videolaryngoscope in Morbidly Obese Patients

Author:

Gaszynski Tomasz1ORCID,Pietrzyk Monika2ORCID,Szewczyk Tomasz3,Gaszynska Ewelina4

Affiliation:

1. Department of Emergency Medicine and Disaster Medicine, Medical University of Lodz, 90-131 Lodz, Poland

2. Department of Anesthesiology and Intensive Therapy, Barlicki University Hospital, Medical University of Lodz, Ulice Kopcinskiego 22, 90-153 Lodz, Poland

3. Department of Gastroenterology, Oncology and General Surgery, Barlicki University Hospital, Medical University of Lodz, 90-131 Lodz, Poland

4. Department of Hygiene and Health Promotion, Medical University of Lodz, 90-131 Lodz, Poland

Abstract

Introduction.The use of videolaryngoscopes is recommended for morbidly obese patients. The aim of the study was to evaluate the Levitan FPS optical stylet (Levitan) vs Lafy-Flex videolaryngoscope (Lary-Flex) in a group of MO patients.Methods.Seventy-nine MO (BMI>40 kg m−2) patients scheduled for bariatric surgery were included in the study and randomly allocated to the Levitan FPS or Lary-Flex group. The primary endpoint was time to intubation and evaluation laryngoscopic of glottic view. Anesthesiologists were asked to evaluate the glottic view first under direct laryngoscopy using the videolaryngoscope as a standard laryngoscope (monitor display was excluded from use) and then using devices. The secondary endpoint was the cardiovascular response to intubation and the participant’s evaluation of such devices.Results.The time to intubation was8.572.66 sec. versus5.790.2 sec. for Levitan and Lary-Flex, respectively (P<0.05). In all cases of CL grade>1under direct laryngoscopy, the study devices improved CL grade to 1. The Levitan FPS produced a greater cardiovascular response than the Lary-Flex videolaryngoscope.Conclusion.The Lary-Flex videolaryngoscope and the Levitan FPS optical stylet improve the laryngeal visualization in morbidly obese patients, allowing for fast endotracheal intubation, but Lary-Flex produces less cardiovascular response to intubation attempt.

Publisher

Hindawi Limited

Subject

General Environmental Science,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3