A Comparative Assessment of Cardiovascular Autonomic Reflex Testing and Cardiac 123I-Metaiodobenzylguanidine Imaging in Patients with Type 1 Diabetes Mellitus without Complications or Cardiovascular Risk Factors

Author:

Didangelos Triantafyllos1ORCID,Moralidis Efstratios2,Karlafti Eleni1,Tziomalos Konstantinos1ORCID,Margaritidis Charalambos1,Kontoninas Zisis1,Stergiou Ioannis1,Boulbou Maria3,Papagianni Marianthi1,Papanastasiou Emmanouel4,Hatzitolios Apostolos I.1

Affiliation:

1. Diabetes Center, First Propedeutic Department of Internal Medicine, Medical School, Aristotle University of Thessaloniki, AHEPA Hospital, Thessaloniki, Greece

2. Laboratory of Nuclear Medicine, Medical School, Aristotle University of Thessaloniki, Papageorgiou Hospital, Thessaloniki, Greece

3. Department of Internal Medicine, Medical School, University of Thessaly, Larissa, Greece

4. Department of Medical Physics, Aristotle University of Thessaloniki, Thessaloniki, Greece

Abstract

Aim. To compare the cardiovascular autonomic reflex tests (CARTs) with cardiac sympathetic innervation imaging with 123I-metaiodobenzylguanidine (MIBG) in patients with type 1 diabetes mellitus (T1DM). Patients and Methods. Forty-nine patients (29 males, mean age 36 ± 10 years, mean T1DM duration 19 ± 6 years) without cardiovascular risk factors were prospectively enrolled. Participants were evaluated for autonomic dysfunction by assessing the mean circular resultant (MCR), Valsalva maneuver (Vals), postural index (PI), and orthostatic hypotension (OH). Within one month from the performance of these tests, patients underwent cardiac MIBG imaging and the ratio of the heart to upper mediastinum count density (H/M) at 4 hours postinjection was calculated (abnormal values, H/M < 1.80). Results. Twenty-nine patients (59%) had abnormal CARTs, and 37 (76%) patients had an H/M_4 < 1.80 (p=0.456). MCR, PI, Vals, and OH were abnormal in 29 (59%), 8 (16%), 5 (10%), and 11 (22%) patients, respectively. When using H/M_4 < 1.80 as the reference standard, a cutoff point of ≥2 abnormal CARTs had a sensitivity of 100% but a specificity of only 33% for determining CAN. Conclusions. CARTs are not closely associated with 123I-MIBG measurements, which can detect autonomic dysfunction more efficiently than the former. In comparison to semiquantitative cardiac MIBG assessment, the recommended threshold of ≥2 abnormal CARTs to define cardiovascular autonomic dysfunction is highly sensitive but of limited specificity and is independently determined by the duration of T1DM.

Publisher

Hindawi Limited

Subject

Endocrine and Autonomic Systems,Endocrinology,Endocrinology, Diabetes and Metabolism