A Validated RP-HPLC Method for Simultaneous Determination of Cefixime and Clavulanic Acid Powder in Pediatric Oral Suspension

Author:

Nepal Utsav12ORCID,Panthi Vijay Kumar3456ORCID,Chaudhary Namindra Prasad27,Chaudhary Samip28

Affiliation:

1. Department of Pharmacy, Kathmandu University, School of Science, Dhulikhel, Nepal

2. Quality Control Department, Royal Sasa Nepal Pharmaceuticals, Bharatpur-18 44200, Chitwan, Nepal

3. Research and Development Department, Royal Sasa Nepal Pharmaceuticals, Bharatpur-18 44200, Chitwan, Nepal

4. Department of Pharmacy, Tribhuvan University, Sunsari Technical College, Sunsari, Nepal

5. Research and Development Department, Asian Pharmaceuticals, Rupandehi, Nepal

6. Research and Development Department, Corel Pharmaceuticals, Rupandehi, Nepal

7. Kantipur College of Medical Science, Tribhuvan University, Sitapaila, Kathmandu, Nepal

8. Tri-Chandra Multiple Campus, Tribhuvan University, Kathmandu, Nepal

Abstract

A new reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of pediatric oral powder formulation containing cefixime (CFX) and clavulanic acid (CVA). In this research, an analytical C18 (4.6 mm × 25 cm), 5 μm column was used for chromatographic separation with a mixture of methanol and water containing disodium hydrogen phosphate in ratio of 20 : 80 v/v as the mobile phase (pH 5.5 adjusted with orthophosphoric acid) at a flow rate of 1.0 mL/min. The detecting wavelength and run time were 220 nm and 15 min, respectively. Moreover, the column temperature was maintained at 30°C. The analytical method was validated prior to meeting the conditions specified by International Conference on Harmonization (ICH) and the parameters were specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness, and solution stability. The calibration curve was found to be linear between the concentration ranges of 0.024–0.036 mg/mL and 0.032–0.048 mg/mL for CFX and CVA, respectively. Furthermore, the LOD and LOQ of CFX were 0.0008 and 0.0025 μg/mL, respectively. Accordingly, LOD and LOQ of CVA were 0.0021 and 0.0065 μg/mL, respectively. The accuracy of the optimized method was examined by recovery studies and the mean recovery was observed to be 98.96% and 99.05% for CFX and CVA, respectively, at 100% spiked level. The repeatability testing for both standard and sample solutions revealed that the method is precise within the acceptable range and the %RSD of the precision was <2%. In addition, the findings of specificity, linearity, accuracy, precision, robustness, LOD, LOQ, and solution stability studies of both CFX and CVA were within the criteria of acceptable limit as well.

Publisher

Hindawi Limited

Subject

Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3