Establishment of Normal Range for Thromboelastography in Healthy Middle-Aged and Elderly People of Weihai in China

Author:

Ni Lina1ORCID,Xue Peng1ORCID,An Changjuan1ORCID,Yu Xia1ORCID,Qu Jiangli1ORCID,Yao Yingjie1ORCID,Li Yingbo1ORCID

Affiliation:

1. Department of Blood Transfusion, Weihai Central Hospital, Weihai 264200, Shandong Province, China

Abstract

TEG can monitor the dynamic changes of blood clot formation and lysis by activating the coagulation system of a small sample of whole blood in vitro. The parameters can reflect the level of coagulation factors, the function of fibrinogen and platelet, and the presence or absence of hyperfibrinolysis. At present, the normal reference range of the parameters of TEG is mainly based on the reference values established by the Western population. Due to the differences in the distribution of ethnic groups, many countries have established their reference ranges for healthy populations. In China, some scholars have tried to establish the corresponding TEG reference range according to the characteristics of the population in different regions. This study tried to establish the reference range for thromboelastography in healthy middle-aged and elderly people of Weihai in China and compare it with the reference range provided by the manufacturer. The fasting venous blood of 454 healthy middle-aged and elderly people was collected, including 239 males and 215 females. The thromboelastography TEG-5000 was used to measure the reaction time (R), coagulation formation time (K), coagulation angle (Angle), and maximum amplitude (MA). The reference range of TEG parameters of middle-aged and elderly healthy males was R: 4.38–8.27 min, K: 1.44–2.82 min, Angle: 48.53–72.17 deg, and MA: 51.95–72.02 mm; respectively, in the females, the normal value was R: 3.43–7.40 min, K: 1.07–2.53 min, Angle: 48.22–77.22 deg, and MA: 53.10–74.58 mm; The difference of R, K, Angle, and MA between the male group and the female group was statistically significant ( P  < 0.05); In this study, if we use the reference range established by the manufacturer, the R specificity for males was 91.6%, K specificity was 98.7%, Angle specificity was 85.8%, and MA specificity was 93.7%; the range for females was 68.4%, 99.5%, 75.8%, and 87.4%, respectively. There are statistically significant differences between R, K, Angle, and MA in middle-aged and elderly healthy women and men. It is necessary to establish a TEG reference range for healthy females and males.

Publisher

Hindawi Limited

Subject

Health Informatics,Biomedical Engineering,Surgery,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3