Screening of Primary School Children for Amblyopia and Amblyogenic Factors in Central Cairo, Egypt

Author:

Rashad Mohammad A.1,Abd Elaziz Khaled M.2,Fawzy Samah Mahmoud1ORCID,Abdel latif Ahmed Abdel Meguid1,Abdel latif Mahmoud Abdel Meguid1

Affiliation:

1. Ophthalmology Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt

2. Community Department, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Abstract

Objective. To measure the prevalence of amblyopia and amblyogenic factors among primary school children and to evaluate distance visual acuity (VA) as a screening test to detect amblyopia and define its cutoff value. Subjects and Methods. A cross-sectional study was conducted on primary school children in two schools in Central Cairo. Children underwent assessment of visual acuity using Landolt broken ring. Comprehensive ophthalmologic examination was performed for amblyopia suspects at the Ophthalmology Department of Ain Shams University Hospitals, including reassessment of best-corrected visual acuity (BCVA) using the same chart. Results. A total of 352 children were examined. Reduced screening VA (amblyopia suspect) was detected in 47 subjects (13.35%) proved amblyopia after comprehensive examination was 1.98% (7 cases). Refractive errors (REs) were present in all suspected and proved amblyopia cases (100%) but was only present in 11.6% of nonamblyopic students (P<0.05). The prevalence of hyperopia in the whole sample was 3.6%, and was 27.6% in subjects with RE. Thirty percent of hyperopic eyes were amblyopic. The prevalence of myopia was 9.3% of the whole sample and 70% of students with RE. Only 9% of myopic eyes were amblyopic. Mild to moderate amblyopia (VA better than 0.2log MAR) was 42.9%, while severe amblyopia represented 57.1%. Conclusion. This study emphasizes the importance of school-based eye care system targeting the detection of amblyopia by application of a fast screening distance VA test with a cutoff value of high sensitivity at log MAR 0.539 (Snellen′s VA equivalent 6/18).

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3