A Comparison of the Ligation Torque Expression of a Ribbonwise Bracket–Archwire Combination and a Conventional Combination: A Primary Study

Author:

Lin Bin1,Jiang Feifei2ORCID,Chen Jie34,Liang Jiaxing1

Affiliation:

1. Department of Orthodontics, Fujian Medical University Union Hospital, Fuzhou, Fujian Province, China

2. Shenzhen Institute of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen, Guangdong Province, China

3. Department of Mechanical and Energy Engineering, Indiana University Purdue University Indianapolis, Indianapolis, IN, USA

4. Department of Orthodontics and Oral Facial Genetics, Indiana University, Indianapolis, IN, USA

Abstract

Objective. To assess the effect of the third-order mechanics of a new ribbonwise bracket–archwire combination using an orthodontic torque simulator. Material and Methods. An orthodontic torque simulator was used to measure the third-order moment of a maxillary central incisor as it changed from a neutral position to a 40° rotation in 1° increment. A new ribbonwise bracket (Xinya, China) was compared with a conventional ligation bracket (American Orthodontic, U.S.A.). The effects of different archwire sizes (i.e., 0.017″ × 0.025″ and 0.019″ × 0.025″) and materials (i.e., nickel-titanium, titanium-molybdenum alloy, and stainless steel) were analyzed. Paired sample t-tests were conducted to compare the moments between the two bracket types corresponding to each of the archwires. The effects of the stiffness of the bracket–archwire complexes were also assessed. Results. Statistically significant differences ( P = 0.05 ) between the moments from the two brackets were found. The ribbonwise bracket–archwire complex generated larger moments when the rotation angle was lower than 30°. The ribbonwise brackets produced moments that could reach a threshold of 5 Nmm more quickly as the angle was increased. The higher the stiffness of the complex, the larger the moment. Conclusion. The ribbonwise bracket–archwire complex reached the moment threshold limits earlier than the conventional complex. When the rotation angle is less than 30°, the ribbonwise bracket–archwire complex generated a greater torque moment in comparison with the conventional complex.

Publisher

Hindawi Limited

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3