Bioresorbable Material in Secondary Orbital Reconstruction Surgery

Author:

Pan Hui1,Zhang Zhenzhen1,Tang Weiwei2,Li Zhengkang1ORCID,Deng Yuan1ORCID

Affiliation:

1. Department of Ophthalmology, Shanghai Ninth People’s Hospital, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai Jiao Tong University School of Medicine, Shanghai, China

2. Department of Ophthalmology, The Second Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China

Abstract

Purpose. To validate the potential of bioresorbable implantation in secondary revisional reconstruction after inadequate primary orbital fracture repair, with assessment of pre- and postoperative clinical characteristics and computed tomography image findings. Methods. A retrospective chart review was conducted on 16 consecutive patients treated for orbital fractures at Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, with inadequate prior surgeries between July 2010 and June 2017; patients who had suffered orbital blowout fractures had undergone primary surgeries elsewhere. Secondary repair of orbital fractures used bioresorbable material following unsatisfactory primary orbital repair. Patients’ demographics, degree of enophthalmos, ocular motility, diplopia test results, primary implants, and surgical complications were reviewed. Results. All 16 patients had primary orbital implants consisting of Medpor, titanium mesh, hydroxyapatite, or poly-L-lactide. Of the 16 cases, 14 had malpositioned implants posteriorly and two had implant infections. Findings following primary surgery included enophthalmos (12/16), diplopia (9/16), intraorbital abscess (2/16), and ocular movement pain (1/16). Mean preoperative enophthalmos was 3.8 ± 0.8 mm. Secondary reconstruction resulted in a mean reduction of enophthalmos by 3.1 ± 0.9 mm (P<0.01). Nine in ten patients experienced improvements in postoperative ocular motility and diplopia following secondary surgery. Intraorbital abscesses and eyeball movement-associated pain were cured. Conclusions. This study demonstrates that secondary orbital reconstruction of previously repaired orbital fractures using bioresorbable material can achieve excellent functional and aesthetic results with minimal complications. Bioresorbable material should be considered in secondary orbital reconstruction when clinically indicated.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3