Abstract

Background. Accurate delineation of tumor margin is essential for complete resection of early gastric cancer (EGC). The objective of this study is to assess the performance of magnifying endoscopy with narrow-band imaging (ME-NBI) for the accurate demarcation of EGC margins. Methods. We searched PubMed, EMBASE, Web of Science, and Cochrane Library databases up to March 2020 to identify eligible studies. The diagnostic accuracy of ME-NBI for EGC margins was calculated, and subgroup analyses were performed based on tumor size, depth of tumor invasion, tumor-occupied site, macroscopic type, histological type, Helicobacter pylori (H. pylori), and endoscopists’ experience. Besides, we also evaluated the negative and positive resection rates of the horizontal margin (HM) of EGC after endoscopic submucosal dissection (ESD) and surgery. Results. Ten studies comprising 1018 lesions were eligible in the databases. The diagnostic accuracy of ME-NBI for the demarcation of EGC margins was 92.4% (95% confidence interval (CI): 86.7%-96.8%). According to ME-NBI subgroup analyses, the rate of accurate evaluation of EGC margins was not associated with H. pylori infection status, tumor size, depth of tumor invasion, tumor-occupied site, macroscopic type, histological type, and endoscopists’ experience, and no statistical differences were found in subgroup analyses. Moreover, the negative and positive resection rates of HM after ESD and surgery were 97.4% (95% CI: 92.1%-100%) and 2.6% (95% CI: 0.02%-7.9%), respectively. Conclusions. ME-NBI enables a reliable delineation of the extent of EGC.

Publisher

Hindawi Limited

Subject

Gastroenterology,Hepatology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3