The Identical External Reference Point Standardized to the Zero-Reference Level for Measuring Both Central and Jugular Venous Pressures: An Observational Study

Author:

Karmacharya Niraj1,Bhattarai Madhur Dev2ORCID,Pradhan Amita3ORCID

Affiliation:

1. Department of Medicine, Civil Service Hospital, Kathmandu, Nepal

2. Department of Medicine, Chitwan Medical College, Bharatpur, Nepal

3. Department of Community Dentistry, People’s Dental College and Hospital, Kathmandu, Nepal

Abstract

Background. Studies report discrepancies between CVP and JVP measurements. The mid-thoracic plane (MTP) at the anterior fourth intercostal space level indicates the zero-reference level (ZRL) for venous pressure measurement, and the midaxillary line (MAL) at fourth intercostal space is a point near the ZRL in the supine position. JVP is usually measured from the sternal angle (SA) with further addition of 5 cm (JVP-SA + 5) and CVP in the supine position from MAL (CVP-MAL). However, no report has compared CVP measured from MTP (CVP-MTP) with CVP-MAL and with JVP from MTP (JVP-MTP) and JVP-SA + 5. Methods. We measured JVP-MTP and JVP-SA + 5 in appropriate reclining positions and subsequently CVP-MTP and CVP-MAL in the supine position blindly in 150 patients. We compared the pressures by Pearson correlation and Bland–Altman plots. Results. CVP-MTP and CVP-MAL demonstrated similar means ( p = 0.129 ), strong positive linear relationship (r = 0.908), and good agreement (near-zero mean difference) with each other. JVP-MTP was about 1 cm higher than JVP-SA + 5 ( p < 0.001 ). JVP-MTP displayed higher correlation coefficients and better agreements with both CVPs than JVP-SA+5. Correlation coefficients and mean differences of both CVPs with JVP-MTP were almost equal, about 0.83 and 1 cm, and with JVP-SA + 5 also almost equal, about 0.72 and 2 cm, respectively. Conclusions. JVP tallies better with CVP examined in the supine position when both are measured from MTP as the identical external reference point (ERP), and MAL can be used as MTP to measure CVP in the supine position. Our findings indicate the way to explore the matching of CVP and JVP to the full extent possible by standardizing their measurements from other identical ERPs to that from the zero-reference level MTP. Their further study in similar higher reclining positions from identical ERPs, such as MTP, MAL, and SA with the addition of higher numbers instead of 5 cm, is warranted standardizing other measurements to that from MTP.

Publisher

Hindawi Limited

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3