Differential Diagnosis between Low-Grade and High-Grade Astrocytoma Using System A Amino Acid Transport PET Imaging with C-11-MeAIB: A Comparison Study with C-11-Methionine PET Imaging

Author:

Nishii Ryuichi123ORCID,Higashi Tatsuya13ORCID,Kagawa Shinya3,Arimoto Maya4,Kishibe Yoshihiko3,Takahashi Masaaki3,Yamada Shigeki5,Saiki Masaaki6,Arakawa Yoshiki7,Yamauchi Hiroshi3,Okuyama Chio3,Hojo Masato8,Munemitsu Toshihiro8,Sawada Masahiro8,Kobayashi Masato9,Kawai Keiichi10,Nagamachi Shigeki211,Hirai Toshinori2,Miyamoto Susumu7

Affiliation:

1. Department of Molecular Imaging and Theranostics, National Institute of Radiological Sciences (NIRS), QST, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan

2. Department of Radiology, Faculty of Medicine, University of Miyazaki, 5200 Kihara Kiyotake-cho, Miyazaki 889-1692, Japan

3. Division of PET Imaging, Shiga Medical Center Research Institute, 5-4-30 Moriyama, Moriyama, Shiga 524-8524, Japan

4. Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan

5. Department of Neurosurgery, Rakuwakai Otowa Hospital, 2 Otowachinjicho, Yamashina-ku, Kyoto 607-8062, Japan

6. Department of Radiology, Japanese Red Cross Otsu Hospital, 1-1-35 Nagara, Otsu, Shiga 520-8511, Japan

7. Department of Neurosurgery, Graduate School of Medicine, Kyoto University, 54 ShogoinKawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan

8. Department of Neurosurgery, Shiga Medical Center, 5-4-30 Moriyama, Moriyama, Shiga 524-8524, Japan

9. Wellness Promotion Science Center, Institute of Medical, Kanazawa University, 5-10-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan

10. Graduate School of Health Sciences, College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-10-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan

11. Department of Radiology, Faculty of Medicine, Fukuoka University, 7-45-1 Nanakuma, Jonan-ku, Fukuoka 814-0180, Japan

Abstract

Introductions. [N-methyl-C-11]α-Methylaminoisobutyric acid (MeAIB) is an artificial amino acid radiotracer used for PET study, which is metabolically stable in vivo. In addition, MeAIB is transported by system A neutral amino acid transport, which is observed ubiquitously in all types of mammalian cells. It has already been shown that MeAIB-PET is useful for malignant lymphoma, head and neck cancers, and lung tumors. However, there have been no reports evaluating the usefulness of MeAIB-PET in the diagnosis of brain tumors. The purpose of this study is to investigate the efficacy of system A amino acid transport PET imaging, MeAIB-PET, in clinical brain tumor diagnosis compared to [S-methyl-C-11]-L-methionine (MET)-PET. Methods. Thirty-one consecutive patients (male: 16, female: 15), who were suspected of having brain tumors, received both MeAIB-PET and MET-PET within a 2-week interval. All patients were classified into two groups: Group A as a benign group, which included patients who were diagnosed as low-grade astrocytoma, grade II or less, or other low-grade astrocytoma (n=12) and Group B as a malignant group, which included patients who were diagnosed as anaplastic astrocytoma, glioblastoma multiforme (GBM), or recurrent GBM despite prior surgery or chemoradiotherapy (n=19). PET imaging was performed 20 min after the IV injection of MeAIB and MET, respectively. Semiquantitative analyses of MeAIB and MET uptake using SUVmax and tumor-to-contralateral normal brain tissue (T/N) ratio were evaluated to compare these PET images. ROC analyses for the diagnostic accuracy of MeAIB-PET and MET-PET were also calculated. Results. In MeAIB-PET imaging, the SUVmax was 1.20 ± 1.29 for the benign group and 2.94 ± 1.22 for the malignant group (p<0.005), and the T/N ratio was 3.77 ± 2.39 for the benign group and 16.83 ± 2.39 for the malignant group (p<0.001). In MET-PET, the SUVmax was 3.01 ± 0.94 for the benign group and 4.72 ± 1.61 for the malignant group (p<0.005), and the T/N ratio was 2.64 ± 1.40 for the benign group and 3.21 ± 1.14 for the malignant group (n.s.). For the analysis using the T/N ratio, there was a significant difference between the benign and malignant groups with MeAIB-PET with p<0.001. The result of ROC analysis using the T/N ratio indicated a better diagnosis accuracy for MeAIB-PET for brain tumors than MET-PET (p<0.01). Conclusions. MeAIB, a system A amino acid transport-specific radiolabeled agents, could provide better assessments for detecting malignant type brain tumors. In a differential diagnosis between low-grade and high-grade astrocytoma, MeAIB-PET is a useful diagnostic imaging tool, especially in evaluations using the T/N ratio. Clinical trial registration. This trial was registered with UMIN000032498.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3