Observation of Clinical Efficacy of Parylene-Coated Occluder Based on Electronic Image of Visual Sensor in the Treatment of Congenital Heart Disease

Author:

Fu Hongdu1,Liang Liming1,Zhuang Huangwei1ORCID,Yang Jiahui1

Affiliation:

1. Department of Cardiac Surgery, Central South University Xiangya School of Medicine Affiliated Haikou Hospital, Haikou, 570208 Hainan, China

Abstract

With the acceleration of people’s life rhythm, the incidence of congenital heart disease is getting higher and higher. This study mainly explores the clinical efficacy observation of parylene-coated occluders based on the electronic image of the visual sensor in the treatment of congenital heart disease. The patient takes a supine position and observes whether the target structure (left ventricular cavity) information is separated from the capture area during rotation, and the angle of the probe is adjusted to ensure that as much target structure information as possible can be obtained during the two-dimensional image acquisition. During the three-dimensional ultrasound sampling process, a total of 60 coaxial images were collected within the range of 180°. To reflect the effect of virtual reality, it is necessary to provide users with interactive operation tools. This research provides two methods, mouse interaction and keyboard interaction. Through these two methods, the effect of the basic virtual endoscope is realized. Xtion’s image registration process is completed inside its PS1080 system-level chip, and all sensor information, color images, and depth images are transmitted to the user host through the USB interface. For example, the point of view can be placed in the heart, because the simulation occlusion must first find a suitable section to better observe and judge the occlusion effect. Therefore, this study uses the mouse interaction method to change the cutting by dragging and rotating the mouse. In the process of releasing the occluder, the parylene-coated occluder can be released after the X-ray and ultrasound examination results are satisfactory, and the delivery long sheath and catheter can be sprinkled and compressed to stop the bleeding. During the operation, the ASD measured by two-dimensional ultrasound after balloon inflation was 24.17 ± 7.94  mm, and the anterior and posterior diameter was 21.30 ± 6.54  mm. This research is helpful for the qualitative and quantitative diagnosis of congenital heart disease.

Publisher

Hindawi Limited

Subject

Electrical and Electronic Engineering,Instrumentation,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3