Abstract

Objectives. To evaluate the potential of contrast-enhanced spectral mammography (CESM) in reducing benign breast biopsy rate, thereby improving resource utilization. To explore its potential as a value-adding modality in the management of BI-RADS 4/5 lesions. Materials and Methods. This was a prospective study conducted between July 2016 and September 2018. Patients with BI-RADS 4/5 lesions detected on conventional imaging (mammogram, digital breast tomosynthesis, and ultrasound) were enrolled for adjunct CESM. Histopathologic correlation was done for all lesions. Additional suspicious lesions detected on CESM were all identified on second-look ultrasound and subsequently biopsied. Images were evaluated independently by two radiologists trained in breast imaging using BI-RADS classification. Presence of enhancement on CESM, BI-RADS score, and histopathology of each lesion were analyzed and tested with the chi-square/fisher-exact test for statistical significance. Results. The study included 105 lesions in 63 participants—1 man and 62 women, an average age of 53.7 ± 10.8 years. On CESM, 22 (20.9%) of the lesions did not show enhancement. All 22 lesions had been classified as BI-RADS 4A and were subsequently proven to be benign. Of the remaining 83 enhancing lesions, 54 (65.1%) were malignant and 29 (34.9%) were benign ( p < 0.05 ). CESM detected 6 additional lesions which were not identified on initial conventional imaging. Four of these were proven malignant and were in a different quadrant than the primary lesion investigated. Conclusion. There is evidence that the absence of enhancement in CESM strongly favors benignity. It may provide the reporting radiologist with greater confidence in imaging assessment, especially in BI-RADS 4A cases, where a proportion of them are in actuality BI-RADS 3. Greater accuracy of BI-RADS grading can reduce nearly half of benign biopsies and allow better resource allocation. CESM also increases the detection rate of potentially malignant lesions, thereby changing the treatment strategies.

Funder

Tan Tock Seng Hospital’s-Pitch for Fund Program

Publisher

Hindawi Limited

Subject

Oncology,Surgery,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3