The Number of Frames on ECG-Gated 18F-FDG Small Animal PET Has a Significant Impact on LV Systolic and Diastolic Functional Parameters

Author:

Eissler Christoph1ORCID,Werner Rudolf A.12ORCID,Arias-Loza Paula1ORCID,Nose Naoko3ORCID,Chen Xinyu124ORCID,Pomper Martin G.5ORCID,Rowe Steven P.5ORCID,Lapa Constantin4ORCID,Buck Andreas K.1ORCID,Higuchi Takahiro123ORCID

Affiliation:

1. Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany

2. Comprehensive Heart Failure Center, University Hospital Würzburg, Würzburg, Germany

3. Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan

4. Department of Nuclear Medicine, University Hospital Augsburg, Augsburg, Germany

5. The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA

Abstract

Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. 18F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 ± 57.7 μl , 380.8 ± 57.2 μl , 398.0 ± 63.1 μl , and 444.8 ± 75.3 μl at 4, 8, 12, and 16 frames, respectively; P < 0.0001 vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed ( P < 0.005 ), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used.

Funder

Okayama University

Publisher

Hindawi Limited

Subject

Condensed Matter Physics,Radiology Nuclear Medicine and imaging,Biomedical Engineering,Molecular Medicine,Biotechnology