Effect of Number and Location on Stress Distribution of Mini Dental Implant-Assisted Mandibular Kennedy Class I Removable Partial Denture: Three-Dimensional Finite Element Analysis

Author:

Jia-mahasap Wissanee1ORCID,Rungsiyakull Chaiy2ORCID,Bumrungsiri Wipahatpong3,Sirisereephap Natthaphorn4,Rungsiyakull Pimduen1ORCID

Affiliation:

1. Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand

2. Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai, Thailand

3. Roi Et Hospital, Roi Et, Thailand

4. Chiang Saen Hospital, Chiang Rai, Thailand

Abstract

Purpose. To investigate effects of number and location on patterns of von Mises stress distribution and volume average stress on abutment tooth, edentulous ridge, mini dental implant, and surrounding bone of mini dental implant-assisted mandibular Kennedy class I removable partial denture. Materials and Methods. Eight three-dimensional finite element models of mandibular Kennedy class I with different numbers and locations of mini dental implants were constructed. Mini dental implants were generated in the area of second premolar, first molar, and second molar, respectively. A static load of 400 N was applied on all models. The von Mises stress and volumetric average stress were calculated by three-dimensional finite element analysis. Result. The minimum volumetric average stress of abutment tooth was found in the model, where there was one mini dental implant at the second molar position and 2 mini dental implants at first molar and second molar positions. The model with three mini dental implants had reduced volumetric average stress of abutment tooth, which was not different from the model with two mini dental implants. However, the minimum volumetric average stress of mini dental implant and surrounding bone were found when three mini dental implants were applied, followed by two and one mini dental implants, respectively. Conclusion. Placing at least one mini dental implant at a second molar position can help reduce stress transferred to the abutment tooth. Stresses around each implant and surrounding bone reduced with increased numbers of mini dental implants.

Funder

Thailand Research Fund

Publisher

Hindawi Limited

Subject

General Dentistry

Reference44 articles.

1. Indications for removable partial dentures: a literature review;B. Wöstmann;International Journal of Prosthodontics,2005

2. Effect of conversion to implant‐assisted removable partial denture in patients with mandibular Kennedy classification Ⅰ: A systematic review and meta‐analysis

3. Maximizing treatment outcomes with removable partial prosthesis through the inclusion of implants and locator attachments;P. A. Fugazzotto;Journal of the Massachusetts Dental Society,2010

4. Mandibular implant-supported removable partial denture with distal extension: a systematic review

5. Mechanical Evaluation of Implant-Assisted Removable Partial Dentures in Kennedy Class I Patients: Finite Element Design Considerations