Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study

Author:

EL-Radaideh Khaled1,Alhowary Ala"a1,Bani Hani Diab1

Affiliation:

1. Department of Anesthesiology, Faculty of Medicine, Jordan University of Science and Technology, P.O. Box 953, Irbid 21110, Jordan

Abstract

Introduction. This study compared streamlined liner of the pharynx airway (SLIPA) and I-gel noninflatable, single-use, supraglottic airway device (SAD) performance in anesthetized, paralyzed adults.Methods. Eighty adults (ASA physical statuses I–III) who were undergoing elective procedures under general anesthesia with an SAD were enrolled in this prospective, randomized, single-blind study. Subjects were randomly and evenly assigned to the SLIPA or I-gel group for intraoperative airway management. Ease and number of insertions, insertion time, oropharyngeal sealing pressure, hemodynamic response, oxygen saturation (SpO2), end-tidal CO2(EtCO2), and peri- and postoperative complications were examined.Results. The SLIPA and I-gel devices were successfully inserted in 100% and 95% of subjects, respectively. In two I-gel subjects (5%), ventilation was not possible after two attempts, but a size 55 SLIPA was successfully inserted in both cases. Forty-two and 38 patients were ultimately included in the SLIPA and I-gel groups, respectively. Insertion time was significantly shorter with the SLIPA (11.19±3.03 s) than with the I-gel (15.05±6.37 s,P=0.003). Oropharyngeal sealing pressure was significantly higher in SLIPA (28.76±3.11 cmH2O) than in I-gel (25.9±3.65 cmH2O) subjects (P=0.001). Blood staining occurred more frequently in SLIPA (n=8, 19.0%) than in I-gel (n=5, 13.2%) patients (P<0.01). Heart rate, mean arterial blood pressure, SpO2, and EtCO2were not significantly different between groups.Conclusion. Although blood staining incidence was higher, SLIPA insertion was easier and faster than I-gel insertion. The SLIPA provided better airway sealing pressure. Both devices had similar mechanical ventilation and oxygenation characteristics and comparable hemodynamic stability. Both noninflatable SADs are useful, but SLIPA rapid insertion and good airway sealing make it an effective alternative to the I-gel.

Publisher

Hindawi Limited

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3