Noncontact Intraocular Pressure Measurement over Bandage Contact Lens and the Effect of Pentacam and Corvis ST’s IOP Correction System

Author:

Cai Xueting12ORCID,Qin Yi1ORCID,Liu Sixiu1ORCID,Cheng Zhewei1ORCID,Lu Fan1,Qu Jia1ORCID,Chen Ding1ORCID

Affiliation:

1. Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China

2. Eye Center of the Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China

Abstract

Purpose. To evaluate the influence of intraocular pressure (IOP) measurement while wearing bandage contact lens (BCL) and the effect of Pentacam and Corvis ST’s correction systems. Methods. It was a prospective comparative study. Forty healthy subjects (40 eyes) were included in this study. Eyes were measured using noncontact tonometer (NCT), Corvis ST, and Pentacam before and after wearing BCL. Pentacam’s five correction formulas (Ehlers formula, Shah formula, Dresden formula, Kohlhaas formula, Orssengo/Pye formula) and Corvis ST’s correction formulas (Ehlers formula and biomechanical corrected formula) were used to correct the IOP values before and after BCL wearing. The IOP values were compared, and the correction effect of different systems were evaluated. Results. The mean age of the subjects was 24.4 ± 0.60 years. The mean IOP obtained by NCT was 14.8 ± 3.2 mmHg before BCL wearing and was 15.7 ± 3.4 mmHg after BCL wearing. The mean IOP was significantly increased after BCL wearing (0.9 ± 2.9 mmHg, P = 0.05 ). Four of the five Pentacam’s correction formulas (except Kohlhaas formula) showed no significant difference in the mean corrected IOP values before and after BCL wearing (all P > 0.05 ). The mean IOP obtained by Corvis ST was 13.7 ± 2.8 mmHg before BCL wearing and was 15.0 ± 4.0 mmHg after BCL wearing. The mean IOP was significantly increased after BCL wearing (1.3 ± 2.4 mmHg, P < 0.05 ). Corvis ST’s correction formula (Ehlers formula other than biomechanical corrected formula) showed no significant difference in the mean corrected IOP values before and after BCL wearing ( P > 0.05 ). Conclusion. The IOP measurements over BCL by NCT and Corvis ST was found to be increased. The correction systems of Pentacam (Ehlers formula, Shah formula, Dresden formula, and Orssengo/Pye formula) and Corvis ST (Ehlers formula) are useful in correcting the IOP measuring deviation induced by BCL wearing.

Funder

Natural Science Foundation Project of Zhejiang Province

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3