Application of Multiple NIRS Imaging Device to the Exercising Muscle Metabolism

Author:

Miura Hajime12,McCully Kevin3,Chance Britton2

Affiliation:

1. Department of Human and Social Sciences, Faculty of Integrated Arts and Sciences, University of Tokushima, 1-1 Minamijyosanjima, Tokushima, 770-8502, Japan

2. Department of Biochemistry and Biophysics, School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA

3. Department of Exercise Science, School of Health and Human Performance, University of Georgia, Athens, GA, 30602-6554, USA

Abstract

Near infrared spectroscopy (NIRS) is a developing technique that measures the balance between muscle oxygen consumption and oxygen supply that is noninvasive and potentially portable. Differential absorption of light in the 600−900 nm region detects the changes in small vessel hemoglobin oxygen saturation and blood volume. Recent developments include the combining of multiple light sources and photodetectors to provide “images” of oxygen saturation and blood volume of wide regions of muscle. Using multiple NIRS imaging device, we monitored localized muscle metabolism during various exercises in the field as well as in the laboratory. In healthy subjects, the regional differences in oxygen saturation and blood volume were detected in the medial head of the gastrocnemius muscle during a standing plantar flexion exercise, consistent with differences in intramuscular pressure. Patients with peripheral arterial disease (PAD) showed slower recovery for both oxygenation and blood volume after exercise. Treatment for PAD resulted in improvements in NIRS-measured recovery times. In summary, NIRS devices have the ability to detect and monitor impaired muscle circulation. In addition, NIRS devices with multiple channels have the potential to evaluate the regional differences in oxygen status. Multiple NIRS imaging devices have the potential to play an important role in monitoring exercise prescription and clinical uses.

Publisher

Hindawi Limited

Subject

Spectroscopy

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com