Urinary PCA3 a Superior Diagnostic Biomarker for Prostate Cancer among Ghanaian Men

Author:

Opoku Mensah Bismark1,Fondjo Linda Ahenkorah1ORCID,Owiredu W. K. B. A.1,Adusei Ben2

Affiliation:

1. Department of Molecular Medicine, KSMD, KNUST, Ghana

2. Urology Unit, 37 Military Hospital, Accra, Ghana

Abstract

Introduction. Prostate cancer is one of the most commonly diagnosed cancers in men. Prostate-specific antigen (PSA) has been the biomarker of choice for screening and diagnosis of prostate cancer. However, inefficiencies exist with its diagnostic capabilities. This study thus evaluated the diagnostic and prognostic potential of urinary PCA3 as an alternative biomarker for prostate cancer in the Ghanaian population. Methods. A hospital-based cross-sectional study was conducted at the Urology Department of the 37 Military Hospital, Accra, Ghana. A total of 237 participants aged 40 years and above with any form of suspected prostate disorder were recruited into the study after written informed consent was obtained. Total serum PSA levels was measured using the electrochemiluminescence method and transrectal ultrasound-guided systematic core needle biopsies were obtained from each study participant. Receiver operating characteristic curve (ROC) analysis was used to evaluate the diagnostic accuracies of serum PSA, DRE, and PCA3 as diagnostic tools for prostate cancer. These three diagnostic tools were also evaluated in various combinations to ascertain the combinations with the best diagnostic accuracy. Results. Prostate cancer was diagnosed in 26.6% of the participants. Benign prostate hyperplasia and prostatitis were diagnosed in 48.5% and 24.9% participants, respectively. DRE had a sensitivity of 93.7% and a specificity of 12.1%. PSA had a sensitivity of 92.1% and a specificity of 16.1%. PCA3 had a sensitivity of 57.1% and a specificity of 85.6% and showed a better accuracy ( AUC = 83.0 ) compared to PSA ( AUC = 60.0 ) and DRE ( AUC = 65.0 ) as individual diagnostic tools. The combination of DRE+PCA3 score had the best diagnostic accuracy ( AUC = 0.80 ) with a sensitivity and specificity of 60.3% and 80.5%, respectively. Conclusion. The urinary PCA3 assay showed a better diagnostic performance compared to serum PSA and DRE. PCA3 as a stand-alone and in combination with DRE could be a suitable complimentary marker in diagnosis and management of prostate cancer.

Funder

37 Military Hospital

Publisher

Hindawi Limited

Subject

Biochemistry (medical),Clinical Biochemistry,Genetics,Molecular Biology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3