Thromboelastography Parameters in Urosepsis: A Retrospective Study

Author:

Qiao Yun1ORCID,Lu Xiaoye1ORCID

Affiliation:

1. Department of Emergency Medicine, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China

Abstract

Thromboelastography (TEG) is usually used to monitor coagulation disorder clinically. It is unclear whether TEG has association with urosepsis and sepsis-induced coagulopathy (SIC). The purpose of this study was to investigate the clinical significance of TEG parameters in urosepsis. 90 patients who were admitted to the Emergency Ward and Emergency Intensive Care Unit (EICU) of Ren Ji Hospital affiliated to Shanghai Jiao Tong University School of Medicine due to urinary infection from February 2014 to February 2022 were retrospectively studied. Urosepsis patients and non-sepsis patients were separately investigated according to the final discharge diagnosis and Sepsis 3.0. At the same time, patients with urosepsis were further divided into groups of SIC and non-SIC based on the definition of SIC. The data of clinical features, laboratory biomarkers, and TEG parameters were collected and analyzed. There were significant differences in white blood cell count, C-reactive protein (CRP), platelet count, procalcitonin (PCT), fibrinogen (FIB), international normalized ratio (INR), prothrombin time (PT), D-dimer, and incidence of urinary tract obstruction between the urosepsis group and non-sepsis group ( P < 0.05 ). In the comparison with non-sepsis group, K value was significantly lower (P = 0.006), while α-angle ( P = 0.003 ) and clot index (CI) ( P = 0.048 ) were significantly higher in urosepsis group. The area under the K value curve excluding urosepsis was 0.667. The areas under CI and α-angle curves for diagnosing urosepsis were 0.682 and 0.621, respectively. The patients in SIC group had significantly higher K value, lower α-angle, and maximum amplitude (MA) than those in non-SIC group ( P < 0.05 ). Coagulopathy is prone to occur in patients with urosepsis. TEG is helpful for assessment of hypercoagulable state in urosepsis and prediction of hypocoagulability in SIC patients implying the dynamic process of DIC.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3