Proposed fibrinogen standard material with purified fibrinogen for plasma fibrinogen measurement on coagulation analyser

Author:

Okuda Masahiro12,Uemura Yahiro2,Tatsumi Noriyuki3,Honda Susumu4

Affiliation:

1. Product Development, Sysmex Corporation, 1-1-2 Murotani, Nishi-ku, Kobe 651-2241, Japan

2. Research and Development Division, International Reagents Corporation, 1-1-2 Murotani, Nishi-ku, Kobe 651-2241, Japan

3. Department of Clinical and Laboratory Medicine, Osaka City University Medical School, Asahi-machi, Abeno-ku, Osaka 545-8585, Japan

4. Faculty of Pharmaceutical Science, Kinki University, 3-4-1 Kowakae, Higashi-Osaka, Osaka 577-8502, Japan

Abstract

A commercially available fibrinogen standard calibrated by a World Health Organization (WHO) reference material is widely used in Japan, and most clinical laboratories use the Clauss method for plasma fibrinogen measurement. However, a current issue in fibrinogen measurement is poor laboratory-to-laboratory variability. To improve the reliability of fibrinogen values and thereby solve the poor precision and accuracy of plasma fibrinogen testing, the present paper develops a simple and large preparation procedure for a suitable fibrinogen standard and quality control material and evaluates their basic performance. With a new procedure getting high purified fibrinogen by glycine precipitation, the calibrator determined by both the Clauss and Jacobson methods produced a fibrinogen concentration of 2.20 g l−1. The total precision of the calibrator was excellent (coefficient of variation 1.4-2.1%) in comparison with current plasma fibrinogen materials from the WHO (#98/612) and with a commercial standard (CV 1.9-3.9%). The within-run precision of the calibrator on the coagulation analysers was 1.7-2.8%. Within-analyser variability among the five instruments had good consistency (mean 2.20 ± 0.022 g l−1; CV 1.0%). The degradation study of the calibrator suggested that storage at 9°C for two years was as predicted. In conclusion, the results show that the calibrator prepared herein can be useful as a candidate Japanese fibrinogen standard and is applicable to automated and semi-automated coagulation analysers. Additionally, it is expected that it will be widely used in Japan by diagnostic manufacturers and clinical laboratories as a recommended secondary standard to estimate a fibrinogen value according to the WHO primary standard.

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,Chemical Engineering (miscellaneous),Analytical Chemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3