Evaluation of Iodinated Contrast Media Use in Abdominal CT Scans in Cancer Assessments: A Cross-Sectional Study in Lomé (Togo)

Author:

Gbande Pihou12ORCID,N’timon Bidamin3,Tchakpedeou Dermane Alassani2,Tchaou Mazamaesso1,Adambounou Kokou2,Sonhaye Lantam2,Agoda-Koussema Lama Kegdigoma4,Adjenou Komlanvi2

Affiliation:

1. Sokodé Regional Hospital Centre, Department of Radiology and Medical Imaging, Sokodé, Togo

2. Campus University Hospital Centre, Department of Radiology and Medical Imaging, Lomé, Togo

3. Kara University Hospital Center, Department of Radiology and Medical Imaging, Kara, Togo

4. Sylvanus Olympio University Hospital Center, Department of Radiology and Medical Imaging, Lomé, Togo

Abstract

Background. There is great variability between centers regarding contrast injection protocols. They should only be injected if they can provide useful information for diagnosis with the necessary and sufficient quantity of iodine. We wanted to know through this study if the use of iodinated contrast media is optimised in abdominal CT scans performed for cancer assessment in Lomé. Materials and Methods. It was a cross-sectional, descriptive, and analytical study with a prospective collection over a period of 6 months in three CT units in Lomé. It involved abdominal CT scans performed for oncological evaluation. Data were reported as the mean ± standard deviation. The Pearson correlation coefficient, ANOVA, chi-square, and the Fisher test were used. Results. A total of 218 examinations were recorded. The female sex represented 56.88% of the patients. The mean age was 50.92 ± 15.78 years. The mean weight was 70.46 ± 15.23 kg. The mean BMI was 24.91 ± 5.32 kg/m2. The examinations were performed with a voltage of 120 kV in 195 cases (89.45%). The mean dose of injected iodine was 0.42 ± 0.09 gI/kg with a dose of 0.40 gI/kg at 80 kV and 0.45 gI/kg at 130 kV. The mean injection rate was 2.90 ± 0.34 mL/s. The mean injected volume was 83.19 ± 7.29 mL. The mean duration of the injection was 30.60 ± 7.39 s. The mean iodine delivery rate was 0.98 ± 0.17 gI/s. There was no saline injection in 152 cases (69.72%). Liver contrast enhancement was satisfactory in 94.5% of cases. There was a strong negative linear correlation between the dose of injected iodine and weight. Conclusions. Optimization guidelines for the use of iodinated contrast media are not always applied. Therefore, monitoring and benchmarking programmes for iodinated contrast injection protocols that involve all radiology personnel should be implemented.

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3