Assessment of Silicone Oil Emulsification: A Comparison of Currently Applied Methods

Author:

Zhao Hongmei123,Chen Qian123ORCID,Yu Jian123ORCID,Wu Kaicheng123ORCID,Zong Yuan123ORCID,Jiang Chunhui123ORCID,Zhu Haohao4ORCID,Xu Gezhi123ORCID

Affiliation:

1. Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, China

2. Key Laboratory of Myopia of State Health Ministry, Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai 200031, China

3. NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China

4. Department of Ophthalmology, Shanghai Fifth People’s Hospital, Fudan University, Shanghai 200240, China

Abstract

Purpose. To compare ultrasound biomicroscopy (UBM), Coulter counter, and B-scan ultrasonography in the evaluation of silicone oil (SO) emulsification. Methods. Patients who underwent primary pars plana vitrectomy with SO tamponade for rhegmatogenous retinal detachment and SO removal were included. UBM images were acquired before the SO removal, and B-scan images were taken after removal. The number of droplets in the first and last 2 mL of washout fluid was analyzed using a Coulter counter. The correlations between these measurements were analyzed. Results. Thirty-four eyes received both UBM and Coulter counter analysis for the first 2 mL of washout fluid, and 34 underwent B-scan and Coulter counter analysis of the last 2 mL washout fluid. The mean UBM grading was 26.41 ± 9.71 (range: 1–36); the mean SO index obtained with B-scan was 5.25 ± 5.00% (range: 0.10–16.49%), and the mean number of SO droplets was 1.26 ± 2.45 × 107/mL and 3.34 ± 4.22 × 106/mL in the first and last 2 mL of washout fluid, respectively. There were significant correlations between UBM grading and SO droplets in the first 2 mL and between B-scan grading and SO droplets in the last 2 mL (all P < 0.05 ). Conclusions. UBM, Coulter counter, and B-scan ultrasonography could all be used in the evaluation of SO emulsification, and their findings were comparable.

Funder

Science and Technology Commission of Shanghai Municipality

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3