Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An In Vitro Study

Author:

Rosas Jose12ORCID,Mayta-Tovalino Frank3ORCID,Malpartida-Carrillo Violeta2ORCID,Degregori Arnaldo Munive4ORCID,Mendoza Roman5ORCID,Guerrero Maria E.6ORCID

Affiliation:

1. Oral Implantology Department, Faculty of Stomatology, Universidad Peruana Cayetano Heredia, Lima, Peru

2. School of Stomatology, Universidad Privada San Juan Bautista, Lima, Peru

3. Postgraduate Department, CHANGE Research Working Group, Faculty of Health Sciences, Universidad Científica del Sur, Lima, Peru

4. Academic Department of Rehabilitative Stomatology, Faculty of Dentistry, Universidad Nacional Mayor de San Marcos, Lima, Peru

5. Postgraduate Department, Faculty of Dentistry, Universidad Nacional Federico Villarreal, Lima, Peru

6. Department of Medico Surgical Stomatology, Faculty of Dentistry, Universidad Nacional Mayor de San Marcos, Lima, Peru

Abstract

Aim. Vertical marginal discrepancy (VMD) influences the success of implant-supported restorations. However, there is little literature that has investigated the influence of geometry and cementing agent on changes in VMD of metal copings on implant abutments. The objective was to evaluate the effect of the geometry of the abutment and cementing agents on VMD. Methods. Cast copings were cemented on implant abutments customized cylindrical (4, 5.5, and 7 mm) and on hexagonal implant abutments (4 mm) cemented or uncemented molded copings were placed (n = 4, totally 64 samples) with different luting agents. The VMD of the copings were measured in the coping-abutment interface at three reference points using a stereomicroscope. The independent Student’s t test was used for comparison between the two different abutment walls. The post hoc statistical analysis was performed by the Tukey test. Results. There was a significant VMD increase between noncemented and cemented cast copings using different luting agents. Abutment geometry and luting agents significantly influenced the VMD p 0.05 . Cylindrical abutment at 7 mm in height cemented with different luting agent tested showed significantly higher VMD values than cylindrical abutments of 4 mm p = 0.019 . Hexagonal abutments with a 4 mm height showed significantly higher VMD values than cylindrical 4 mm abutments using zinc oxide noneugenol and glass ionomer cements p = 0.032 . Conclusions. Abutment geometry and luting agents influence the VMD of cast copings cemented on implant abutment. The higher the cylindrical abutment, the greater the VMD, and hexagonal wall abutments promote greater marginal gap.

Publisher

Hindawi Limited

Subject

General Dentistry

Reference29 articles.

1. Implant survival and success rates in patients with risk factors: results from a long-term retrospective study with a 10 to 18 years follow-up;F. De Angelis;European Review for Medical and Pharmacological Sciences,2017

2. A quarter of a century as a trendsetter in implant dentistry

3. Screw retained vs. cement retained implant-supported fixed dental prosthesis

4. Technical and biological complications of single-molar implant restorations

5. Effect of different angulations and collar lengths of conical hybrid implant abutment on screw loosening after dynamic cyclic loading

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献