Determination of Cefoperazone Sodium in Presence of Related Impurities by Improved Classical Least Squares Chemometric Methods: A Comparative Study

Author:

Naguib Ibrahim A.12,Darwish Hany W.34

Affiliation:

1. Pharmaceutical Chemistry Department, Faculty of Pharmacy, University of Tabuk, Tabuk 71491, Saudi Arabia

2. Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University, Alshaheed Shehata Ahmad Hegazy Street, Beni-Suef 62514, Egypt

3. Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia

4. Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo 11562, Egypt

Abstract

A comparative study is established among 4 chemometric models depending on classical least squares (CLS) approach, namely, spectral residual augmented CLS (SRACLS), net analyte processing CLS (NAP-CLS), orthogonal signal correction CLS (OSC-CLS), and direct orthogonal signal correction CLS (DOSC-CLS). The comparison is expressed through analysis of a case study dataset of UV spectral data of Cefoperazone Sodium (CEF) and its two related impurities: in pure powder form and in pharmaceutical dosage form. Four-level three-factor experimental design was established for optimum analysis. The adopted experimental design gave rise to a training set consisting of 16 mixtures (containing different ratios of interfering species). To test the prediction power of the suggested models, an independent test set consisting of 9 mixtures was used. The presented results show the ability of the proposed models to quantify CEF in presence of two related impurities with high accuracy and selectivity (103.76±1.03,102.07±0.91,101.61±0.72, and101.60±0.72for SRACLS, NAP-CLS, OSC-CLS, and DOSC-CLS, resp.). Dosage form analysis results were compared statistically to a published HPLC methodology showing insignificant difference in terms of precision and accuracy, indicating the suggested models reliability and their suitability for quality control analysis of drug product. Compared to other models, OSC-CLS and DOSC-CLS models gave more accurate results with lower prediction error for test set samples.

Funder

King Saud University

Publisher

Hindawi Limited

Subject

General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3