Implant Stability Changes for Nonsubmerged and Submerged Protocols for a Single Implant Mandibular Overdenture Using Ball Attachment

Author:

Salah Ahmed1ORCID,Foda Karim1,Abdalla Mohamed Farouk1ORCID,Aal Marwa Abdel1ORCID,Naguib Amr1ORCID,Nabi Nouran Abdel1ORCID

Affiliation:

1. Prosthodontics Department, Faculty of Dentistry, Cairo University, Giza, Egypt

Abstract

Objectives. To compare the changes in implant stability for the nonsubmerged (NS) and submerged (S) protocols for the single implant retained mandibular overdenture using ball attachment throughout a 24-month follow-up. Materials and Methods. Eighty completely edentulous patients were seeking to improve retention of their lower complete denture by installing a single implant in the midline of the completely edentulous mandible. At the day of implant installation, patients were randomized into 2 groups using sealed envelopes: the nonsubmerged (NS) and submerged (S) group. After a 3-month healing period, all patients were randomized using sealed envelopes into ball attachment and CM-LOC attachment. The Periotest readings (PTV) was recorded using the Periotest M device and was recorded every 3 months for the first year and then annually in the second year. The scope of this clinical trial focused only on results of the ball attachment. The Mann–Whitney U test was used for comparison between study groups for independent samples. Two-sided p values less than 0.05 was considered statistically significant. Results. There was no statistically significant difference in the mean change in PTV reading between the NS and S group at the different follow-up intervals. Initially, at the day of pickup (baseline) and 3-month follow-up, the mean PTV reading for the NS was greater than that of the S group (−4.471 ± 1.489, −4.391 ± 1.4727 ( p = 0.913 )), while the S group has shown a greater improvement in PTV than the NS group after 6-month follow-up and continued throughout the 24-month follow-up (−5.730 ± 1.7804, −50855 ± 1.2581 ( p = 1 )). Conclusion. Both the nonsubmerged and the submerged healing protocol have shown reliable Periotest readings using ball attachment for a single implant retained overdenture. The submerged group has resulted in a greater improvement in Periotest readings after the 12- and 24-month follow-up period when compared to the nonsubmerged group although this improvement was not statistically significant.

Funder

Cendres & Metaux Company

Publisher

Hindawi Limited

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3