Affiliation:
1. Guangxi Key Laboratory of Intelligent Control and Maintenance of Power Equipment, Electric Power Research Institute of Guangxi Power Grid Co.Ltd., No.6-2, Minzhu Road, Xingning, Nanning 530023, Guangxi, China
Abstract
In recent years, with the rapid economic development, the development speed of all walks of life has entered a new level, and the power industry has also developed rapidly. Driven by market demand, China’s power transmission range and power transmission capacity will enter a new level. At the same time, the problems brought about by the development of the power system are equally severe. Due to the large load density in individual areas, the detection of short-circuit current must be improved as an important issue. The purpose of this paper is to study how to improve the practical model of short-circuit current calculation of photovoltaic power plants, so that it can be well applied to the current high-density current detection in China. Therefore, this paper improves the recursive least squares (RLS) algorithm and applies it to the practical model of short-circuit current calculation of photovoltaic power plants and describes the improvement process of the algorithm in detail. At the same time, this paper designs relevant experiments and analysis to count the data of the improved RLS algorithm in the short-circuit current calculation of the actual photovoltaic power station and combines the data of this part to test and analyze the ability of the algorithm. The experimental results in this paper show that the improved RLS algorithm has a very good improvement in the calculation accuracy of the short-circuit current calculation of photovoltaic power plants in the actual model calculation. At the same time, the calculation efficiency is also improved, and the current tracking effect is also improved by 7%.
Funder
China Southern Power Grid
Subject
Electrical and Electronic Engineering,Energy Engineering and Power Technology,Modeling and Simulation
Reference27 articles.
1. Calculation of the admissible short circuit current for the protected wires of an ohl;A. P. Vikharev;Power Technology and Engineering,2018
2. Three-phase short-circuit current calculation for power transmission system with high penetration of converter-type sources;J. Ma;Dianli Xitong Zidonghua/Automation of Electric Power Systems,2019
3. Short-circuit current calculation of inverter interfaced distributed generator based on voltage control in distribution network;W. Xie;Journal of Chongqing University,2017
4. Fault characteristics of full power inverted sources and its short‐circuit current calculation model
5. Recursive regularisation parameter selection for sparse RLS algorithm
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献